Programming should be done when monitor power supply is on.
Note!
In the monitor apartment numbers within a range 1...255 can be programmed. Programming
a number bigger than 255 is not possible. Number 0 should not be programmed!
Each such attempt will cause programming of default number 63.
Programming is done by means of pushbuttons: PROG (in the monitor rear part), LOCK
and CONTROL as well as two colour LED.
Functions of pushbuttons during programming monitor number:
PROG
- entering programming mode
CONTROL
- entering programmed value
LOCK
- confirmation of entered value, passing to next programming
stage
Arrangement of pushbuttons and signalling diode is shown on dwg. 1 and 2.
Programming new number requires the following activities:
4.1. We should press three times pushbutton PROG on a plate in the monitor rear part
(see dwg.2) this should be done within 3 sec. Monitor passes to programming
mode which is siganalled by a short flash of LED diode.
4.2.
Setting number of hundreds
. Pushbutton CONTROL should be pressed as many
times as there are hundreds in the programmed number (0,1 or 2). Each pressing
is signalled by green flashing of LED diode. Then entering number of hundreds
should be finished by pressing pushbutton LOCK which will be confirmed by longer
flashing of a diode. If the number of hundreds is equal to 0 (programmed number
smaller than 100) pushbutton LOCK should be pressed immediately and the next
step should be realized entering the number of tens.
4.3.
Setting number of tens
. Pushbutton CONTROL should be pressed as many times
as there are tens in the programmed number (0,1 or 2). Each pressing is signalled
by green flashing of LED diode. Then entering number of tens should be finished by
pressing pushbutton LOCK which will be confirmed by longer flashing of a diode. If
the number of tens is equal to 0 pushbutton LOCK should be pressed immediately
and the next step should be realized entering the number of unities.
4.4.
Setting number of unities.
Pushbutton CONTROL should be pressed as many times
as there are unities in the programmed number. Each pressing is signalled by green
flashing of LED diode. Then entering number of unities should be finished by pressing
pushbutton LOCK which will be confirmed by longer flashing of a diode. If the number
of unities is equal to 0 pushbutton LOCK should be pressed immediately.
4.5.
Finishing the programming procedure. Checking the number.
Green diode starts flashing as many times as there are hundreds, tens and unities
in the programmed number. Longer break means passing to next digit in the
programmed number while longer flashing of red diode means a zero value of
a given digit. After finishing reproducing the programmed number the diode will light
at the same time in two colours, then one colour will extinguish and the colour of
a diode will correspond to volume level of acoustic signal before starting the
programming procedure.