Programming should be done when monitor power supply is on.

Note!

In the monitor apartment numbers within a range 1...255 can be programmed. Programming
a number bigger than 255 is not possible. Number “0” should not be programmed!
Each such attempt will cause programming of default number “63”.

Programming is done by means of pushbuttons: PROG (in the monitor rear part), LOCK
and CONTROL as well as two colour LED.
Functions of pushbuttons during programming monitor number:

PROG 

- entering programming mode

CONTROL

- entering programmed value

LOCK

        - confirmation of entered value, passing to next programming 

  stage

Arrangement of pushbuttons and signalling diode is shown on dwg. 1 and 2.

Programming new number requires the following activities:

4.1. We should press three times pushbutton PROG on a plate in the monitor rear part

(see dwg.2) – this should be done within 3 sec. Monitor passes to programming
mode which is siganalled by a short flash of LED diode.

4.2. 

Setting number of hundreds

. Pushbutton CONTROL should be pressed as many

times as there are hundreds in the programmed number (0,1 or 2). Each pressing
is signalled by green flashing of LED diode. Then entering number of hundreds
should be finished by pressing pushbutton LOCK which will be confirmed by longer
flashing of a diode. If the number of hundreds is equal to 0 (programmed number
smaller than 100)  pushbutton LOCK should be pressed immediately and the next
step should be realized – entering the number of tens.

4.3. 

Setting number of tens

. Pushbutton CONTROL should be pressed as many times

as there are tens in the programmed number (0,1 or 2). Each pressing is signalled
by green flashing of LED diode. Then entering number of tens should be finished by
pressing pushbutton LOCK which will be confirmed by longer flashing of a diode. If
the number of tens is equal to 0 pushbutton LOCK should be pressed immediately
and the next step should be realized – entering the number of unities.

4.4. 

Setting number of unities.

 Pushbutton CONTROL should be pressed as many times

as there are unities in the programmed number. Each pressing is signalled by green
flashing of LED diode. Then entering number of unities should be finished by pressing
pushbutton LOCK which will be confirmed by longer flashing of a diode. If the number
of unities is equal to 0  pushbutton LOCK should be pressed immediately.

4.5. 

Finishing the programming procedure. Checking the number.

      Green diode starts flashing as many times as there are hundreds, tens and unities

in the programmed number. Longer break means passing to next digit in the
programmed number while longer flashing of red diode means a zero value of
a given digit. After finishing reproducing the programmed number the diode will light
at the same time in two colours, then one colour will extinguish and the colour of
a diode will correspond to volume level of acoustic signal before starting the
programming procedure.

 LASKOMEX PPUH, ul. D•browskiego 249, 93-231 •ód•, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

MVC-6850

Installation and activation

Summary of Contents for MVC-6850

Page 1: ...Installation and activation MVC 6850...

Page 2: ...uld be connected with power supply cut off Prior to monitor hanging the number should be programmed description below in item 4 Monitor can be supplied directly from individual power supply adaptor 13...

Page 3: ...PPUH ul D browskiego 249 93 231 d tel 42 671 88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl MVC 6850 Installation and activation Dwg 1 MVC 6850 monitor view Dwg 2 MVC...

Page 4: ...ll call back to monitor and the fitter will be able to check the functioning of acoustic track and electro catch 3 Gate drive control Pressing a PROG button causes a short circuit terminal BR to the G...

Page 5: ...d entering the number of tens 4 3 Setting number of tens Pushbutton CONTROL should be pressed as many times as there are tens in the programmed number 0 1 or 2 Each pressing is signalled by green flas...

Page 6: ...is the only line load 7 Monitor control Monitor is equipped with three step control of acoustic signals calling from external panel calling from floor panel door bell colour saturation contrast and pi...

Page 7: ...upply 13 5V DC 1A CVR 2 IN MON4 MON1 NC1 L L NC2 Doorbell pushbutton MVC 6850 230V AC 50Hz Local power supply of monitor 13 5V DC 1A Additional camera Additional device relay coil 12V DC max 50 mA LAS...

Page 8: ...l recycling saves raw materials and reduces generating of wastes This product was marked with a symbol of crossed dustbin according to European Directive 2002 96 WE on used electric and electronic equ...

Reviews: