![Laskomex ISD-02 Installation And Activation Download Page 6](http://html1.mh-extra.com/html/laskomex/isd-02/isd-02_installation-and-activation_3783659006.webp)
Page
6
ISD-02
Driver installation was completed successfully.
The device has been installed and assigned to the first available COM port (see
Device Manager
)
4.2 Data exchange
Data (settings of electronic cassette) exchange from entry phone system to PC takes place through:
4.2.1. Connection EC electronic cassette ISD-02 interface
connect ISD-02 interface to the CN1 socket in EC electronic cassette using appropriate cable
(CN1* in cassettes manufactured till August 2009 is situated on the edge of PCB circuit of EC
- cable should be insert with coding inset at the top)
electronic cassette automatically enters into data exchange mode - on the display of external
panel
caption will be shown
in ISD-02 software choose the direction of data exchange
4.2.2. Connection EC electronic cassette MLX module
connect MLX module to the CN1 socket in EC electronic cassette (CN1* in cassettes manufactured
till August 2009 is situated on the edge of PCB circuit of EC - MLX should be insert with coding
inset at the top)
on the display of external panel
caption will be shown.
NOTE!
Since software version 6.8 of EC-2502 electronic cassette or 7.1 of EC-3100 electronic
cassette one should enter P-7 procedure in programming mode.
Using external panel keyboard one should choose the appropriate option:
1
- data backup from electronic cassette to the internal memory of MLX module -
2
- displays the CPU serial number of configuration saved in MLX -
3
- data upload from MLX module to the electronic cassette -
after choosing the direction of data transfer (upload or backup) one have to choose:
1
- copying all the parameters of el. cassette including electronic keys database -
3
- copying only identifiers database -
the selection should be confirmed by pressing the field with a symbol of key process of writing
or reading will begin which is signalled by flashing caption
or properly
after copying data
caption will be shown and short acoustic signal will appear