background image

Page 

2

CP-2502/2503/2510/2511/2513/2520/2521/2523/2530/2533

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

1. SAFETY AND USAGE CONDITIONS

- Prior to the installation please read the following instruction.
- Electric installation should be done in accordance with PN-IEC-60364-1 norm by the

authorized person. Installation should not be directly exposed to atmospheric electrostatic
discharge.

- It is forbidden to connect the panel to other installations, with exception of the application

recommended by the producer.

- Self maintenance is only permitted for qualified persons. Device maintenance by unauthorized

persons may result in the lost of warranty.

- It is forbidden to connect power supply from sources with different parameters than

recommended by the producer to panel clamps. The producer is not responsible for any
lost occurred due the usage of improper power supplies.

- Signals from the digital entry phone system  should not be directly connected to RTV sets,

because of risk of devices and system damages.

- View distortions occurred when raining or just after rain are temporary, they are associated

with water gathering near camera lens and should not be perceived as symptom of device
damage.

- Outdoor panel should not be sealed (i.e silicon), cause it worsens ventilation and leads to

corrosion.

- Dirt on the keyboard (snow, mud) may cause faulty operation - in such case dirt should be

immediately removed.

- Do not clean the panel with gasoline, solvents or strong detergents as it may cause damage

of the device surface.

2. OUTDOOR PANEL ASSEMBLY

 

Panel installation can only be carried out when power supply is off !

 If possible outer panel should be installed inside wind shields as it is better secured

against atmospheric factors.

 Lens located in the camera panel must not be pointed directly to strong light source (the

sun, strongly lightened street lamp), cause it may seriously or completely limit observation
of speakers faces.

 Panel should be installed on the proper altitude providing comfortable usage of the device

for all users. Suggested altitude is approx. 150 cm. Install the device lower in order to
enable usage for disabled and invalids.

 When installing panels make certain to provide proper ventilation for each unit. For that

reason it is not recommended to seal the space between the frame and the panel with
silicon or foam etc.

 When installing panel with the tenants list make certain to write down names before

riveting the device.

Mounting under the plaster.

In the wall cut out an opening of the dimensions that would enable to place the external
panel freely in it and the frame should completely cover the opening edges. Then 4 holes
o 10 mm should be drilled for strut pins. The tightening force (important when the cut out
opening is deeper than depth of cassette) should be matched to avoid bending of a frame.
Make electrical connections and fix panel with a keyboard by two M4 screws and two rivets
(included in the set).

Summary of Contents for CP-2502 Series

Page 1: ...OF PANELS CP 2502xxx CD 2503xxx CP 2510xxx CP 2513xxx CP 2511xxx CP 2520xxx CP 2523xxx CP 2521xxx CP 2530xxx CP 2533xxx DIGITAL ENTRY PHONE SYSTEM CP 2530 CP 2533 CP 2520 CP 2523 CP 2510 CP 2513 CP 2...

Page 2: ...ud may cause faulty operation in such case dirt should be immediately removed Do not clean the panel with gasoline solvents or strong detergents as it may cause damage of the device surface 2 OUTDOOR...

Page 3: ...N panel b in CP 2530 CP 2533 panels 3 DIGITAL ENTRY PHONE SYSTEM CD 2502 ADJUSTMENT The elements of entry phone system are preliminarily adjusted and unless it is necessary the position of potentiomet...

Page 4: ...s see installation and usage manual of system CD 2502 Jumpers settings Set properly jumper JP2 on the electronic panel plate see figure 3 Figure 3 External panel setting the kind of used display and s...

Page 5: ...uld be considered and set properly jumper JP2 and JP3 figure 3 NOTE Correct work of RFID function in CP 25xxR panel ensure cooperation only with EC 2502R electronic cassette 5 TECHNICAL DATA El supply...

Page 6: ...mps 50m 150m 250m EC H CVP 1 L L LM L 0 5mm 2x0 5mm 3x0 5mm NC1 NC2 C C 0 5mm YTKSY UTP LAN T11 XzTKMXpw YTKSY UTP LAN T11 XzTKMXpw Clamps Distance CP EC CVP 15m Kx Kx 0 5mm X GX X GS 0 5mm C C NC1 NC...

Page 7: ...AC 0 8 A Wh i te Br o w n AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brow n Br o w n L L K6 K5 K4 K2 K3 K1 X GS K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VS GS NC1 NC2 C C CS CVP 1 SUBORDINATE ENTRANCE Electro...

Page 8: ...DA 2V DA 3V 10 100 634 210 80 130 130 42 48 48 48 48 10 otw O 5 5 56 65 48 185 210 130 80 38 31 10 100 424 210 80 130 130 42 48 48 48 48 10 otw O 5 5 56 65 38 31 185 42 100 214 10 130 48 48 5 otw O 5...

Page 9: ...8 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl DAX1 1 DAX1 2H DAX1 2V Figure 12 Dimensions of over plaster casing in vertical position for CP 2510 and CP 2513 panels Fi...

Page 10: ...88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl DAX2 1 DAX2 2H DAX2 2V Figure 14 Dimensions of panels CP 2520 CP 2523 NP2522 and NP2521 Figure 15 Dimensions of over pl...

Page 11: ...0 2533 LASKOMEX PPUH ul D browskiego 249 93 231 d tel 42 671 88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl Figure 18 Dimensions of over plaster casing in vertical pos...

Page 12: ...s product was marked with a symbol of crossed dustbin according to European Directive 2002 96 WE on used electric and electronic equipment Used equipment cannot be placed with other wastes from househ...

Reviews: