Adjustable mirror mounts
RS-800RGY: Loosen setscrews, then adjust with X/Y adjustable screws. Make sure beam is centered
on scanner mirrors. Adjust Z-screw simultaneously Tighten setscrews.
RS 1000 RGB: use set screws to align colours.
When combining beams (RGY/RGB laser), first make sure the beams are (roughly) on the same spot
on the mirrors/dichros. Then use a test pattern (e.g. rectangle) to do fine adjustment. For
adjustments, always turn output power down (if possible).
Troubleshooting
Problem
Possible reason
Damaged part
Replacement
No power
Fuse blown
Fuse
09-00-3001-01
Power supply defective
+-24V
16-03-0039-00
Music mode not working
Microphone defective
Microphone
16-03-0001-00
Control board defective
Control board
26-2A-LT12V2-00
Potentiometer defective
Potentiometer
04-03-0104-01
CPU defective
IC
00-89C516RD-00
X and/or Y axis no
deflection
Scanner defective
Galvo
15-01-2215-00
CPU defective
IC
00-89C516RD-00
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Scanner driver board defective
Scanner driver board
26-2A-6800A-00
Laser dark or dim
Lenses / mirrors dirty
Clean with alcohol
Laser diode defective
Laser diode
Inquire
Control board defective
Control board
26-2A-LT12V2-00
Configuration / wrong mode
Check configuration (see
paragraph control panel)
No output
Configuration / wrong mode
Check configuration (see
paragraph control panel)
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Display board defective
Display
26-2A-YX2012DI-00
Pins 4 and 17 of the ILDA signal
not connected
See below
Laser does not switch to ILDA mode:
•
The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface
manual
•
The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
•
Use an adapter, that connects pins 4 and 17.
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+
-5V..+5V
14 X-
+5V..-5V
2 Scanner Y+
-5V..+5V
15 Y-
+5V..-5V
3 Intensity/B
0V..+2.5V
16 Intensity/Blanking-
0..-2.5V
4 Interlock A
17 Interlock B
5 Red+
0..2.5V
18 Red-
0..-2.5V
6 Green+
0..2.5V
19 Green-
0..2.5V
7 Blue+
0..2.5V
20 Blue-
0..-2.5V
8 – 12 Not used
23-24 Not used
13 S5V, max. 20 mA
25 GND Signal ground
Please note