Laserworld ES-400 G Manual Download Page 4

Manual / Bedienungsanleitung: ES-400 G 

Version / Stand: 12/2010 

Page / Seite 4 of / von 10

Make sure to use the correct voltage. Always use a grounded mains connection. Don’t use a remote 
controlled or other electronically switched main connection. Don’t use together with large appliances 
(especially fog machines/hazers) on the same mains. 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-rope 
must be fixed. 
In some countries, the operator must notify the accidence insurance and the authority for industrial 
safety, before operating a laser. For more information, contact the relevant authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to safety 
reasons! 
If this device will be operated in any way differently than described in this manual, the product may 
suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
dangers like short-circuit, burns, electric shock, etc. 
Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or damp and 

dusty environment, don’t place liquid filled receptacles on the device. Projector should be put in a 
water-proof housing when operated outside.  
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid 
condenses in the housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes whether 

the outlet air gets too warm. Regularly check the inside for dust deposits, especially around the fans. 
Let laser cool off 10 minutes after 2 hours of operation, to ensure maximum lifetime for the diode. Be 
careful not to direct stage lights toward the laser (especially moving heads), this can cause 
overheating. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 
When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down.

 

Operation 

Caution – use of controls or adjustments or performance of procedures other than those 
specified herein may result in hazardous radiation exposure. 

Connect the power cable to the mains. Connect an emergency switch to the interlock connector, 
open shutter, and turn key to on position. The red LED on the front panel should turn on, and the 
laser beam will exit through the front opening – be careful.  

Control panel 

Safety switch Laser on/off 

Remote lock, connect emergency switch 

Dip switch, mode/DMX address selection 
(see below) 

DMX 512 in/out 

Microphone sensitivity 

Microphone 

Operating modes 

The following operating modes can be selected from the DIP switch on the backside of the device: 

Dip switch 

Mode 

0,0,0,0,0,0,0,0,0,0 

Automatic, beam effects 

1,0,0,0,0,0,0,0,0,0 

Music active, beam effects 

0,1,0,0,0,0,0,0,0,0 

Automatic, graphics 

1,1,0,0,0,0,0,0,0,0 

Music active, graphics 

x,x,x,x,x,x,x,x,x,1 

DMX 

“Music activ”: 

patterns are changed/animated to the beat of the music. Sensitivity can be adjusted at the back panel. 

“Automatic mode”: 

patterns are changed automatically 

“DMX“: 

DMX512 Mode. Use the first 9 switches to select the address: 

x  

x  

x  

x  

x  

x  

x  

x  

1  

2  

4  

8  

16  

32  

64  

128  

256 

e.g. 1000 0000 01, DMX mode address 1 (1+0+0+0+0+0+0+0+0+0) 

Summary of Contents for ES-400 G

Page 1: ...ns 3 Operation requirements 3 Operation 4 Control panel 4 Operating modes 4 DMX control 5 Maintenance cleaning 5 Troubleshooting 6 Technical specifications 6 Please note 6 Lieferumfang 7 Hinweise zur...

Page 2: ...rantielabels erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t grossen Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer e...

Page 3: ...ctly into the light source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL cause eye damage Warn...

Page 4: ...me for the diode Be careful not to direct stage lights toward the laser especially moving heads this can cause overheating Distance between laser aperture and projection screen should be not less than...

Page 5: ...ockwise 192 255 Rotate clockwise 8 Vertical rotation 0 No effect 1 127 Static 128 255 Dynamic 9 Horizontal rotation 0 No effect 1 127 Static 128 255 Dynamic 10 Move 0 No effect 1 127 Move horizontal i...

Page 6: ...W Operation modes DMX 512 automatic music mode Lasersources aircooled DPSS laser Optical power at the laser max 400mW 300mW 532nm green Beam ca 3mm 1mrad Laser class 3b Scanning system Galvo system 2...

Page 7: ...en nicht verdeckt sein 7 Netzstecker Kaltger tebuchse zug nglich halten Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs ffnungen m ssen beim Betrieb des Geh u...

Page 8: ...dip switch an der Geh user ckseite k nnen Sie folgende Betriebsmodi eistellen Dip switch Modus 0 0 0 0 0 0 0 0 0 0 Automatisch Beameffekte 1 0 0 0 0 0 0 0 0 0 Musiksteuerung Beameffekte 0 1 0 0 0 0 0...

Page 9: ...dingt zuvor vom Netz Schauen Sie niemals direkt in den Laserstrahl Zum ffnen entfernen Sie die Schrauben an den Seitenteilen und der R ckseite entfernen Sie 2 F sse auf einer Seite ziehen Sie den Stec...

Page 10: ...ei Der Benutzer des Ger ts muss die lokalen Sicherheitsbestimmungen und die Warnhinweise in der Betriebsanleitung beachten Sch den die durch unsachgem sse Handhabung entstehen unterliegen nicht dem Ei...

Reviews: