background image

Manual / Bedienungsanleitung: EL-50/100 G DMX / EL-150R DMX 

Version / Stand: 01/2010 

Page / Seite 5 of / von 12

 
The address is the sum of all activated numbers, see the following example settings (the white 
rectangle represents the position of the switch)

 

Addr 

switch 

addr 

switch 

 

 

 

65 

 

 

17 

 

 

113 

 

 
The laser uses 8 DMX channels, so make sure that the next device uses an address that doesn’t 
overlap with this range. E.g. when using address 1, make sure the next device uses at least address 
number 9. 

Channel 

Value 

Function 

 0 – 63 

Sound mode 

64 – 127 

DMX mode  

128 – 191 

Automatic mode 

 
 

192 – 255 

Laser off 

0 - 255 

Patterns / animations 

0 - 255 

 

0 - 255 

Line speed 

0 - 255 

Point speed 

0 - 255 

X-position 

0 - 255 

Y-position 

0..255 

Size 

 
Please note, that not all effect channels work with every pattern. 

E.g. you can’t change 

position with dynamic patterns, or move a vertical line in y direction, etc.

 

Maintenance / cleaning 

Always disconnect from the mains when the device is not in use or before cleaning it. 
Open the device by removing the 2 upper screws on one side panel (one front and one back), then 
bend side panel outward and slide out the top. Remove any deposits of dust, especially at the fan. 
Check for condensed fog fluid inside. If so, clean and rearrange the position of laser and/or hazer. 

Mirrors need cleaning when a “halo” is noticeable around the beam or an unusual high amount of 
diffuse light can be seen inside the device. 

Clean the mirrors with window cleaner and a paper towel.  

Never look directly into the light source. Always disconnect from the mains when the 
device is not in use or before cleaning it. 

Summary of Contents for EL-50G DMX

Page 1: ...tion requirements 4 Operation 4 Sound automatic mode 4 DMX control 4 Maintenance cleaning 5 Troubleshooting 6 Technical specifications 6 Please note 6 EU Declaration of Conformity 7 Lieferumfang 8 Hin...

Page 2: ...erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t gro en Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer eine Steckdose...

Page 3: ...ou open the device for cleaning always disconnect from mains HEALTH HAZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock These lasers are considered a de...

Page 4: ...the outlet air gets too warm Regularly check the inside for dust deposits especially around the fans Let laser cool off 10 minutes after 2 hours of operation to ensure maximum lifetime for the diode B...

Page 5: ...8 0 255 Size Please note that not all effect channels work with every pattern E g you can t change position with dynamic patterns or move a vertical line in y direction etc Maintenance cleaning Alway...

Page 6: ...DMX diode laser EL 150R DMX Optical power at the laser EL 50G DMX max 50mW 35mW 532nm green EL 100G DMX max 100mW 70mW 532nm green EL 150R DMX max 150mW 120mW 655nm red Beam ca 3mm 1mrad Laser class...

Page 7: ...rrespondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval i...

Page 8: ...n Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs ffnungen m ssen beim Betrieb des Geh uses frei sein 3 Benutzen Sie das Ger t nicht wenn sichtbare Besch digu...

Page 9: ...Lasers befindet sich das Ger t nach dem Einschalten im Sound Modus Hierbei werden die Muster soundgesteuert gewechselt Um die Empfindlichkeit der Musiksteuerung einzustellen benutzen Sie den Einstell...

Page 10: ...s nicht jeder Effektkanal bei allen Mustern aktiv ist Z B kann bei dynamischen Mustern die Position nicht ge ndert werden bei der vertikalen Linie nicht die Y Position etc Reinigung Reinigen Sie das G...

Page 11: ...istung am Laser EL 50G DMX maximal 50mW 35mW 532nm gr n EL 100G DMX maximal 100mW 70mW 532nm gr n EL 150R DMX maximal 150mW 120mW 655nm rot Laserklasse 3b Betriebsmodi DMX 512 Automatik Modus Musik Mo...

Page 12: ...Richtlinien der EN 60825 1 Laserschutzklassen gepr ft Nach erfolgter Installation ist eine weitere Pr fung des gesamten Aufbaus unerl sslich und muss nach den Richtlinien der EN 60825 1 3 und korrespo...

Reviews: