User manual: CS-250RGY
Rev: 02/2009
page6 of 8
Maintenance / cleaning
Always disconnect from mains before cleaning/opening the laser. Regularly clean the
interior from dust, especially ensure operation of the fans. Use a sponge with
alcohol, rather than wet cloth or other chemical liquid, to clean the mirrors. Be
careful, even light scratches reduce the output power of the laser. Mirrors need
cleaning, when a “halo” is noticeable around the beam, or an unusual high amount
of diffuse light can be seen inside the device.
Technical specifications
•
Lasersources:
aircooled DPSS Laser
•
Power (of the diodes):
typical 250mW, minimum 200mW, 65mW 532nm
green,
135mW 650nm red
•
Laserclass:
3b
•
Modes:
ILDA, DMX 512, auto, music active
•
ILDA:
25pin ILDA standard Sub-D shaped 25pin connector
•
Galvos:
20k scanspeed
•
DMX 512:
12 channels
•
Patterns:
249
•
Scanangle:
ca. 40°
•
Beam:
ca. 3mm/1mrad
•
Accessories:
power cable, key switch, interlock plug, manual
•
Input voltage:
AC 100~240V 50/60Hz
•
Power consumption:
50W
•
Size:
280 x 220 x 150
mm (W x D x H)
•
Weight:
3.5kg
•
Operating temperature:
10°-35°C
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+
-10V..+10V
14 X-
+10V..-10V
2 Scanner Y+
-10V..+10V
15 Y-
+10V..-10V
3 Intensity/B
0V..+2.5V
16 Intensity/Blanking- 0..-2.5V
4 Interlock A
17 Interlock B
5 Red+
0..2.5V
18 Red-
0..-2.5V
6 Green+
0..2.5V
19 Green-
0..2.5V
7 Blue+
0..2.5V
20 Blue-
0..-2.5V
8 – 12 Not used
23-24 Not used
13 S5V, max. 20 mA
25 GND Signal ground