Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid condenses in the 
housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C 

. In a new installation, check after some 15-30 minutes whether the outlet 

air gets too warm. Regularly check the inside for dust deposits, especially around the fans. Let laser cool off 10 
minutes after 2 hours of operation, to ensure maximum lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer. 
When returning laser to dealer/manufacturer always use original packaging. 
Maintenance should be performed every 15-day period. See “cleaning” further down. 

To ensure maximum lifetime of the laser: 
Don’t overheat the laser: 

•  

Always ensure good ventilation 

•  

Don’t have stage lights (especially moving heads) directed towards the laser 

•  

Regularly clean the fans and the interior from dust 

•  

In a new installation check the temperature after 30 minutes of operation 

Keep the laser dry 

•  

Make sure fog/hazer fluid doesn’t condensate inside the laser - fog has to be in front of the laser – not 

inside 

•  

A few days after (each new) installation, open the cover to check if fluids condensate inside 

•  

If fluids condensate inside, reposition the laser or fogger/hazer 

Turn the device off, when not used. The diode is on, when the device is on. Even if it is not lit. 
If the laser is equipped with a remote connector, connect an emergency switch to the Remote lock connector 
on the backside, the switch has to interrupt the connection between pins 1 and 2 to turn off the laser. If no 
emergency switch is used, insert the 9 pin dongle instead. If the laser has no remote lock, or the 9 pin dongle 
is used, use an emergency switch in the mains connection. 

Using the laser 

Caution – use of controls or adjustments or performance of procedures other than those specified 
herein may result in hazardous radiation exposure. 

Rigidly mount projector. Projector can be mounted in any position. 
Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the 9-pin connector 
(Interlock connector) on the backside (pins 1 and 2). If you do not wish to connect an emergency switch, 
connect the 9-pin plug instead, and use an emergency switch in the mains connection. 
Open shutter and turn key to on position, the laser beam will now exit through the front opening – be careful. 

Control panel 

Main switch 

Remote lock, connect emergency switch 

Dip switch, mode/DMX address selection 
(see below) 

DMX 512 in/out 

Microphone sensitivity 

Mains connection 

ILDA in/out 

Operating modes 

The following operating modes can be selected from the DIP switch on the back side of the device: 

Dip switch 

Mode 

1,0,0,0,0,0,0,0,0,1 

Automatic 

0,0,0,0,0,0,0,0,0,1 

Music active 

X,X,X,X,X,X,X,X,X,1 

DMX 

“Music active”: 

patterns are changed/animated to the beat of the music. Sensitivity can be adjusted at the back panel. 

“Automatic mode”: 

patterns are changed automatically 

“DMX“: 

DMX512 Mode. Use the first 9 switches to select the address: 

x  

x  

x  

x  

x  

x  

x  

x  

1  

2  

4  

8  

16  

32  

64  

128  

256 

e.g. 1000 0000 01, DMX mode address 1 (1+0+0+0+0+0+0+0+0+0) 
0010 0100 01, DMX mode address 36 (0+0+4+0+0+32+0+0+0) 
In music active mode the speed can be set with switches 3 and 4: 
Off, off 

Auto speed 

Off, on 

Mid 

On, off 

Slow 

On, on 

Fast speed 

Summary of Contents for CS-1500 RGB

Page 1: ...ION 2 Using the laser 3 Control panel 3 Operating modes 3 DMX control 4 ILDA mode 4 Maintenance cleaning 4 Troubleshooting 4 ILDA signal 5 Technical specifications 5 Please note 5 Hinweise zur Inbetri...

Page 2: ...es and heights ensure the MPE is never exceeded in the public area When setting up the laser make sure the laser is affixed firmly to avoid vibrations Warning labels on the device Laser radiation Read...

Page 3: ...equipped with a remote connector connect an emergency switch to the Remote lock connector on the backside the switch has to interrupt the connection between pins 1 and 2 to turn off the laser If no e...

Page 4: ...hannel 1 64 191 ILDA mode When an ILDA compatible interface is connected to the laser the laser is automatically switched to ILDA mode Output is then controlled by a PC running laser control software...

Page 5: ...mW 150mW 532nm green 500mW 655nm red 450mW 445nm blue Beam green ca 2mm 1 5mrad red ca 5mm 2 5mrad blue ca 3x0 5mm 2x4mrad Laser class 4 Scanning system Galvo system 30 000 PPS at 4 Scanangle max 40 W...

Page 6: ...ben Leitung Sorgen Sie immer f r eine ausreichende Bel ftung Insbesondere d rfen die Bel ftungs ffnungen nicht verdeckt sein Netzstecker Kaltger tebuchse zug nglich halten Stellen Sie sicher dass das...

Page 7: ...Laserstrahl schauen Nur in geschlossenen R umen betreiben Am Strahlaustritt Bestrahlung vermeiden Austritt von Laserstrahlung Inbetriebnahme Verbinden Sie das Ger t mit dem Stromnetz schliessen Sie e...

Page 8: ...altet das Ger t in den ILDA Modus Die Steuerung erfolgt ber geeignete PC Software Die Scanner sind f r ca 10000 PPS bei 20 25 optisch eingestellt Wenn Sie die Scanner schneller betreiben verkleinern S...

Page 9: ...ot 450mW 445nm blau Laserklasse 4 Betriebsmodi DMX 512 Automatik Modus Musik Modus ILDA Scannnersystem Galvos 30000pps bei 4 Scanwinkel max 40 DMX 512 12 Kan le Strahldaten gr n 2mm 1 5mrad rot ca 5mm...

Page 10: ...LAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil Oberhofen SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau www laserworld com i...

Reviews: