LaserPoint AHA-5-D12 Instruction Manual Download Page 1

LaserPoint srl  –  20090  Vimodrone  -  Via Burona, 51  –  tel.  02 27 40 02 36  -  fax. 02 25 02 91 61  -e-mail:  

[email protected]

 –www.laserpoint.eu 

 

LaserPoint s.r.l.-

 

OEM Amplified Sensor Heads Instruction Manual 

 - All Rights Reserved

                          

1

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Rele

a

se

:  

  

 JUNE 

.0

6

 

O

O

E

E

M

M

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

S

S

e

e

n

n

s

s

o

o

r

r

s

s

 

 

w

w

i

i

t

t

h

h

 

 

A

A

n

n

a

a

l

l

o

o

g

g

u

u

e

e

 

 

B

B

u

u

i

i

l

l

t

t

-

-

i

i

n

n

 

 

A

A

m

m

p

p

l

l

i

i

f

f

i

i

e

e

r

r

 

  

Instruc

tio

n Manu

al

 

E

d

ition

 0

5

 –

Ju

ly

 201

7

 

Summary of Contents for AHA-5-D12

Page 1: ...serpoint it www laserpoint eu LaserPoint s r l OEM Amplified Sensor Heads Instruction Manual All Rights Reserved 1 06 O OE EM M T Th he er rm ma al l S Se en ns so or rs s w wi it th h A An na al lo og gu ue e B Bu ui il lt t i in n A Am mp pl li if fi ie er r Instruction Manual Edition 05 July 2017 ...

Page 2: ... TABLE OF CONTENTS TABLE OF CONTENTS 2 1 GENERAL 3 2 INSTALLING THE AH OEM SENSOR HEAD SERIES 3 2 1 GENERAL 3 2 2 Amplifying Speed Up Electronic Circuit 4 2 3 Supply voltages Output Signal 5 2 3 Installation of Air Convection Cooled Series 6 2 4 Installation of Water Cooled Series 6 2 5 Mechanical Dimensions useful for Installation 7 3 STANDARD OEM SENSOR HEADS 8 4 SAFETY 15 5 WARRANTY 15 6 LIMITE...

Page 3: ...aged or if you suspect that it does not operate properly Operating environment Allow at least 5 minutes of warm up time after the turn on to achieve maximum stability of the electronics Refer to the specs attached to this manual for environmental and operating conditions 2 INSTALLING THE AH OEM SENSOR HEAD SERIES Installation must be performed by an operator qualified to the use of electrically op...

Page 4: ... since both Electrical Offsets and the Time Constant which governs the speed up of signal have been optimized in house Should any modification be done you are kindly requested to contact LaserPoint before Trimmer P3 sets the Gain and thus the correct final calibration of the head If LaserPoint is informed about the laser wavelength being used a pre setting is provided so that just the final fine t...

Page 5: ...m link to the machine The color codes for wires are Description Old Color Code New Color Code Output 0 5 VDC White Brown Common GND Green Orange Supply 7 12 VDC Blue Black Supply 7 12 VDC Red Red From 2012 a new cable with different Color Code is used Output Voltage Full Scale 5V Min Detectable Voltage 5mV Total Sensitivity 5V Max Power Value for sensor in use Max Power Value 2W to 200W depending ...

Page 6: ...ional heat sink 1 A custom heat sink may be installed either onto the existing rear flange or more efficiently directly against the main body of housing after the four M3 screws and the rear flange have been removed Always use a thin layer of heat transfer compound between the rear flange and the detector main body to increase thermal conductivity 2 4 Installation of Water Cooled Series Mechanical...

Page 7: ...Reserved 7 2 5 Mechanical Dimensions useful for Installation AH Sensor Head Series have two foot prints 50x50mm and 60x60mm The lateral fixing holes are M3x6 and are always centered respect to the body side The four assembly screws on the front and back side are M3 and are placed at 90 degrees on a diameter of 53mm in the heads with 50x50mm body and on a diameter of 68mm in the heads with 60x60mm ...

Page 8: ...e Full Scale 5V Sensitivity 1V W Min Detectable Voltage 5mV Amplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Conduction Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHA 10 D12 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Max Continuous Power 10 W Max Energy 10 J long pulses Dimensions 50x5...

Page 9: ...able Voltage 5mV Amplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Conduction Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHA 5 D20 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Max Continuous Power 5 W Max Energy 5 J long pulses Dimensions 50x50x30mm Sensitive Diameter 20mm Available Absor...

Page 10: ...oltage 5mV Amplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Conduction Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHA 20 D20 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Max Continuous Power 20 W Max Energy 20 J long pulses Dimensions 50x50x30mm Sensitive Diameter 20 mm Available Absorbe...

Page 11: ...mplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Water 0 5 lit min 22 C Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHW 50 D20 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Large Area or Expanded Beams Max Continuous Power 50 W Max Energy 50 J long pulses Dimensions 50x50x30mm Sensitive Dia...

Page 12: ...mplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Water 0 5 lit min 22 C Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHW 50 D25 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Large Area or Expanded Beams Max Continuous Power 50 W Max Energy 50 J long pulses Dimensions 60x60x30mm Sensitive Dia...

Page 13: ...mplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Water 1 5 lit min 22 C Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHW 200 D20 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Max Continuous Power 200 W Max Energy 200 J long pulses Dimensions 50x50x33mm Sensitive Diameter 20 mm Available Abso...

Page 14: ...mplifier Input Voltages 7VDC to 12VDC or 14 to 24VDC floating Response Time 0 100 1 sec Linearity 1 b Cooling Water 1 5 lit min 22 C Notes a Tested 10 6µm b Detector centrally irradiated 50 of useful surface AHW 200 D25 TYPICAL LASERS Diode Lasers Diode arrays CO2 Nd Yag Ion Lasers Max Continuous Power 200 W Max Energy 200 J long pulses Dimensions 60x60x33mm Sensitive Diameter 25 mm Available Abso...

Page 15: ...suse During the warranty period LaserPoint srl will repair or at its sole option replace any OEM sensor head or its components that prove to be defective provided the parts are returned to LaserPoint customer service facility or another facility authorized by LaserPoint Any attempt by an unauthorized person to alter or repair the product voids the warranty No other expressed warranty is given by L...

Page 16: ...two brominated flame retardants Products placed on the EU market on or after 1 July 2006 must not contain more than the limits of lead cadmium mercury hexavalent chromium polybrominated biphenyls PBB and polybrominated diphenyl ethers PBDE as specified by RoHS directive LaserPoint Plus 2 power energy meter is a product compliant to RoHS European Directive 8 European Union WEEE Directive WEEE 2002 ...

Reviews: