Lasermet LS-10-12 Instruction Manual Download Page 7

LS-10-12 Laser Beam Shutter Instruction Manual 

 

CEB00XXX-53-000 

Page 7 of 9

 

Issue 3          19 January 2021 

 

Specifications 

 
Supply Voltage   

 

12 – 24VDC  

(9 – 25VDC) 

Current Consumption   

180mA max. at 12VDC 

 
Status Output Voltage   

As incoming supply 

Status Output Current Rating 

100mA max. non-inductive 

 

Optical Specification 

 
Maximum Optical Power 

20W ave. 

Maximum Beam Diameter 

15mm 

Maximum Power Density  

as per DoC 

 

 

Dimensions 

 

 

 
 
Dimensions are approximate. Values given as ‘typical’ are average values measured across a number 
of  samples  and  are  not  guaranteed.  Lasermet  reserve  the  right  to  alter  any  specification  without 
prior notice. 
 
 
 

Summary of Contents for LS-10-12

Page 1: ...LS 10 12 Laser Beam Shutter Instruction Manual CEB00XXX 53 000 Issue 3 19 January 2021 LASERMET LS 10 12 SHUTTER INSTRUCTION MANUAL LASER BEAM SHUTTER...

Page 2: ...00XXX 53 000 Page 2 of 9 Issue 3 19 January 2021 LASERMET LS 10 12 Instruction Manual Contents 1 Declaration of Conformity 3 2 Safety Warnings 4 3 Concept 5 4 Installation 5 5 Wiring 5 6 Operation 6 7...

Page 3: ...tives and standards and found to comply Lasermet certifies that this product complies with the basic requirements for health and safety as provided by the following directives and standards Directives...

Page 4: ...be made to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not co...

Page 5: ...al power or any other drives or devices for return to the safe mode Lasermet provides a full range of laser interlock equipment including control systems interlock switches illuminated warning signs l...

Page 6: ...ordered Contact Lasermet for other control methods 6 Operation When the power supply to pin 1 of the shutter comes on the middle yellow LED will light The green LED will also light indicating that th...

Page 7: ...tage As incoming supply Status Output Current Rating 100mA max non inductive Optical Specification Maximum Optical Power 20W ave Maximum Beam Diameter 15mm Maximum Power Density as per DoC Dimensions...

Page 8: ...inst defects in workmanship for 12 months Damage or defects caused by other factors are not covered For example industrial contamination incorrect cleaning storm damage Consequential loss is not cover...

Page 9: ...ted to provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any...

Reviews: