LMH Series Rotary Lasers • 15
2:
After installing the fi rst piece of ceiling trim, attach the wallmount
to it. Be sure the wallmount is secure to the trim.
3:
Press the Power button. If the out-of-level indicator is blinking,
press the manual grade button to put the unit into automatic mode.
Allow the unit to self-level.
4:
Adjust the distance of the unit from the grid, typically 1.5-inch
(38mm) below the grid. Loosen the adjustment screw and slide the
unit up/down on the wall mount. When the desired height has been
reached, tighten the adjustment screw to secure the unit.
5: Install the ceiling grid. Attach the magnetic laser target to the
ceiling trim being installed. Adjust the height of the trim until the
laser beam strikes the target.
Note
: Placing the unit into Scan Mode will make installation easier and
more effecient.
To place the unit in Scan Mode, press the Scan Mode button until the
rotating laser head stops. Press and hold either clock-wise or
counter-clock-wise Head Positioning button until the laser beam
moves to the working area. Press the Scan Mode button until the
rotating beam is scanning the necessary angle.
4.2 Procedures for Laydown Applications (LMH600 Only)
1:
Place the unit in the laydown position on a fl at, level surface.
2:
Press the Power button. If the "Out-of-Level" indicator is blinking,
LMH600 Shown