background image

Tip 6: Ensure that you have really detected a stud. To do so,

check on both sides whether other studs are present at
equal distances, usually at 30, 40 or 60 cm. Also check
that it is a stud by scanning at several places directly
above and below the position of the first find. 

Tip 7: Textured ceilings: The ceiling must be covered with

cardboard to protect it. In this case, use the DeepScan
function. 

CAUTION:

If electric wires or metal or plastic pipes are

located near or in contact with a plaster fibreboard panel,
they may be identified by the StarFinder as studs. Always
switch off the power supply when working near electric wires. 

SPECIAL THINGS TO NOTE WITH VARIOUS MATERIALS

It may not be possible to detect wooden studs or joists
through the following materials: 

• Ceramic floor tiles 

• Fitted carpeting with padded backing 

• Wallpaper with metal fibres or metal foil 

• Freshly painted, damp walls. These must have dried for at
least one week.

5. AC-SCAN

The StarFinder is able to detect the electrical fields of live
wires. 

• Select AC-SCAN (button 6).

• Hold the tool in the air so that it is pointing away from any

live wires. 

LED CAL (3) flashes: Press the calibration button (7) and
wait until calibration is completed. CAL OK: LED 

CAL 

(3)

lights permanently.

Move the tool slowly across the surface. Please refer also
Tip 1 on next page.

StarFinder

ENGLISH

9

Summary of Contents for StarFinder

Page 1: ...nde ledninger D tection de c bles Localizaci n de cables Localizzazione di cavi elettrici Lokalizowanie przewod w Stud Scan AC Scan 4 cm Metall Metal Metaal Metal M tal Metal Metallo Metal Holz Wood H...

Page 2: ......

Page 3: ...epth B AC SCAN For localising live wires directly beneath the pla ster or behind wooden panels and other non metallic panelling It is not possible to detect live wires in dry walls with metal studs 4...

Page 4: ...e is no stud Otherwise the LED CAL 3 will blink To verify Move the tool to another position a few centimetres away and start measuring again Tip 3 The maximum display does not light up even though the...

Page 5: ...switch off the power supply when working near electric wires SPECIAL THINGS TO NOTE WITH VARIOUS MATERIALS It may not be possible to detect wooden studs or joists through the following materials Ceram...

Page 6: ...t To achieve maximum sensitivity start by placing the device in a position which is known not to be near live wires Tip 5 With the Set Button 4 the sensivity can be adjusted The highest sensivity max...

Page 7: ...ltiFinder Pro Art Nr 080 960A MeterMaster Pro Laser Art Nr 080 930A AQua Master AQM Pro 200 Art Nr 029 01 00A Metal Scan 5 cm AC Scan 2 cm 110 220 Volt 10 cm 1 cm 3 cm 4 cm Stud Scan www laserliner co...

Page 8: ...ione di travi 3 Localizzazione di cavit 4 Sicurezza nella scelta del punto in cui praticare il foro Elektroniczny przyrz d lokalizacyjny 1 Lokalizowanie przewod w 2 Lokalizowanie belek 3 Lokalizowanie...

Reviews: