Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line.
The precision is within the specified tolerance if the deviation between the laser line and the plumb line
is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and switch on the cross laser. Mark
point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark
point C. Check whether the horizontal line from point C is level with point B
to within ± 1 mm. Repeat the process by turning the laser to the left.
Regularly check the adjustment before use, after transport and after extended periods of storage.
!
EU directives and disposal
This device complies with all necessary standards for the free movement
of goods within the EU.
This product is an electric device and must be collected separately for disposal
according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
Technical data
(Subject to technical alterations. 01.17)
Self-levelling range
± 3°
Precision
± 0.2 mm / m
Laser wavelength, horizontal laser line
660 nm
Laser wavelength, vertical laser line
640 nm
Laser wavelength plumb laser
635 nm
Laser class
2 / < 1 mW
Power supply
4 x 1.5 V alkaline batteries (Type AA) / battery
Operating time
approx. 14 hours
Operating temperature
0°C ... +50°C
Storage temperature
-10°C ... +70°C
Weight (incl. batteries)
550 g
Dimensions (W x H x D)
63 x 115 x 119 mm