LaserRangeMaster Pocket Pro
13
Error codes:
Too much ambient light.
The target is too far away.
Target is too dark or too much ambient light.
Use a re
×
ecting material as target for the measurement.
Temperature is too high: > 40 °C.
Temperature is too low: < 0 °C
Replace the battery.
The device is moving too much to measure.
Pythagoras parameter error: The hypotenuse is shorter as one
side of a right triangle.
Err001:
Err002:
Err003:
Err004:
Err005:
Err006:
Err007:
Err008:
Inside measurement range
O,3 m - 60 m
Accuracy
+ 2 mm
Laser class
2 < 1mW
Laser wavelength
635 nm
Power supply
4 x AAA 1,5 Volt batteries
Dimensions
112 x 59 x 35 mm
Weight
190 g
Auto switch-off
20 s for laser / 5 min for device
Operating temperature
0°C – 40°C
Storage temperature
-20°C – 70°C
Article number
080.943A
Technical data:
(Subject to technical change without notice 01.2011)
GB
Important notices:
• The laser points to the location that will be measured. No objects may
get into the laser‘s line of measurement.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
• The device cannot be used in strong sunlight.
• The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
• In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
• Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
• Measurements made through glass (window panes) can falsify
measurement results.
• An energy-saving function switches the device off automatically.