16
B
C
2,5 m
< 2 mm = OK
Technical data
(Subject to technical alterations)
Self-levelling range
± 2°
Precision
± 2 mm / 10 m
Laser wavelength linelaser (green)
532 nm
Laser wavelength plumb laser (red)
650 nm
Laser class / line laser output power
2M / < 5 mW
Laser class / plumb laser output power
2 /
÷
1 mW
Power supply
Lithium-ion rechargeable battery
Battery operating time (all lasers on) 3P / 5P approx. 10 h / approx. 4 h
Battery recharging time
approx. 5 h
Operating temperature
0°C ... + 40°C
Storage temperature
-10°C ... + 60°C
Weight (incl. battery)
1,7 kg
Dimensions (W x H x D)
135 x 135 x 215 mm
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5
m length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within the
specified tolerance if the deviation between the laser line and the plumb line is
not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and
mark point C. Check whether the horizontal line
from point C is level with point B to within ± 2 mm. Repeat the process by
turning the laser to the left.
Regularly check the adjustment before use, after transport and after
extended periods of storage.
!