LaserLiner DigiLevel Plus 25 Manual Download Page 7

DigiLevel Plus

07

Technical data

Electronic measuring precision

± 0,1° at 0° … 1° 
± 0,1° at 89° … 90° 
± 0,2° at 1° … 89°

Display accuracy

1 decimal place

Vial

± 1 mm/m

Operating conditions

0 ... 50°C, 80%rH, no condensation, 
max. working altitude 2000 m above sea level

Storage conditions

-20 ... 70°C, 80%rH, no condensation

Auto power off

after 3 minutes

Power supply

2 x 1.5V LR03 (AAA)

Dimensions (W x H x D) 

25

240 x 66 x 30 mm

Dimensions (W x H x D) 

40

400 x 66 x 30 mm

Dimensions (W x H x D) 

60

600 x 66 x 30 mm

Weight 

25

315 g (incl. batteries)

Weight 

40

495 g (incl. batteries)

Weight 

60

675 g (incl. batteries)

Subject to technical change without notice. Rev21W32

EU directives and disposal

This device complies with all necessary standards 
for the free movement of goods within the EU.
This product is an electric device and must 
be collected separately for disposal according 
to the European Directive on waste electrical 
and electronic equipment.
Further safety and supplementary notices at: 

http://laserliner.com/info?an=diglevpl

Backlighting

The backlighting is switched ON/OFF by pressing and holding button (6).

9

Auto Off function

In order to preserve the batteries, the measuring device switches off automatically if it is 
left idle for 3 minutes.

EN

Danger – powerful magnetic fields

Powerful magnetic fields can adversely affect persons with active medical implants 
(e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical 
clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons, the applicable national 
stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic 
fields“ (occupational health and safety - electromagnetic fields) in the Federal Republic 
of Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at 
least 30 cm away from the magnet.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents 
and solvents. Remove the battery(ies) before storing for longer periods. Store the device in 
a clean and dry place.

Calibration

The meter needs to be calibrated on a regular basis to ensure it produces accurate measurement 
results. We recommend carrying out calibration once a year. Contact your distributor or the 
UMAREX-LASERLINER service department.

Summary of Contents for DigiLevel Plus 25

Page 1: ...DigiLevel Plus DE 02 240 400 600 magnetic AutoSound DE FR NL IT EN ES DA PL 02 14 08 20 05 17 11 23 FI TR SV UK PT RU NO CS 26 38 32 44 29 41 35 47 ET SL BG SK RO HU EL HR 50 62 56 68 53 65 59 71...

Page 2: ...wenn eine oder mehrere Funktionen ausfallen oder die Batterieladung schwach ist Sicherheitshinweise Umgang mit elektromagnetischer Strahlung Das Messger t h lt die Vorschriften und Grenzwerte f r die...

Page 3: ...n Grad und mm m umgeschaltet 3 Das Ger t ist richtig kalibriert wenn es in beiden Positionen 0 und 180 die gleichen Messwerte anzeigt ndern des Winkel Referenzwertes Mit Taste 2 k nnen Neigungen bertr...

Page 4: ...er und an elektromechanischen Ger ten z B Magnet karten mechanischen Uhren Feinmechanik Festplatten verursachen Hinsichtlich der Einwirkung starker Magnetfelder auf Personen sind die jeweiligen nation...

Page 5: ...vice must no longer be used if one or more of its functions fail or the battery charge is weak Safety instructions Dealing with electromagnetic radiation The measuring device complies with electromagn...

Page 6: ...he display and the required reference angle is set The slope can now be transferred to other objects Press button 2 again to deactivate the angle reference C F measured value The ambient temperature i...

Page 7: ...olding button 6 9 Auto Off function In order to preserve the batteries the measuring device switches off automatically if it is left idle for 3 minutes EN Danger powerful magnetic fields Powerful magn...

Page 8: ...E Umarex GmbH Co KG Laserliner M hnestra e 149 59755 Arnsberg Germany Tel 49 2932 638 300 Fax 49 2932 638 333 info laserliner com Umarex GmbH Co KG Donnerfeld 2 59757 Arnsberg Germany Tel 49 2932 638...

Reviews: