1
7
6
9
3
4
17
5
8
2
10
11
12
Operator Controls
1.
Key Switch
Controls power access.
Requires key to operate
2.
Power / Mode Button
1
st
depression=Laser on steady
2
nd
depression=Laser on blinking
3
rd
depression=Laser off
3.
Remote Interlock Interface Port
Provides connection source for external
laser shut off switch.
4.
Shorting Bar – Remote Interlock Port
Remove if wiring the system for remote
laser shut off.
5.
Power Connector to 12vdc
6.
3 amp Protection Fuse
(Size= 20 x 5mm)
7.
Rear Panel Redundant LED Emissions Indicator
8.
Mounting Hole 5/8 x 11
9.
Horizontal Lock Knob
10.
Horizontal Tangent Knob
11.
Vertical Lock Knob
12.
Vertical Tangent Knob
13.
Redundant Dual LED Emissions
Indicator (Front)
Indicates emission mode of the laser
using dual LED redundancy.
14.
Laser Aperture
15.
Fan Lens (Optional)
16.
Scope (Optional)
17.
Purge Valve Set at Factory
Do Not
tamper with. Will void warranty
Warning!
Laser is filled with dry nitrogen to prevent moisture.
Do not open or tamper with purge valve, front, rear or
bottom covers. No user or non-certified persons shall
access interior of laser! Removal of covers is
prohibited and voids the factory warranty.
Start-up Procedure
Turn the Key Switch (1) to right, 3 minutes
prior to use. This puts the laser module in the
“preheat” mode to bring it up to operating
temperature. The laser Main Power / Mode
button (2) and Redundant LED emissions
indicator light (7) will slow blink while it’s
warming up. Once the lights stop blinking and
go out, the laser will be ready to turn on. Push
(2) Main Power / Mode Switch once for steady
beam, twice for blinking and third shuts off
the laser
*NOTE:
Redundant Dual LED Emissions
Indicator lights (13) will always be on steady
during warm up period and while in use.
13
14
15
16
Page 2
Summary of Contents for GL3000T
Page 14: ...Notes ...