background image

                                                                                                User Manual 

                           

                                Hadfield Management Ltd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           

             

         

 

 

 

 

Please read this manual carefully before you initially start-up! 

 

Summary of Contents for club scene

Page 1: ...User Manual Hadfield Management Ltd Please read this manual carefully before you initially start up ...

Page 2: ...arts are included Club Scene laser projector 1pc Power cable 1pc DMX signal cable 1pc User manual 1pc Specifications Laser type Green Laser Diode Pumped Solid Stated Laser DPSSL Red Laser Semiconductor Diode Laser Laser class Class IV Laser life 5000 Hours Cooling ways Air cooled Color Red 650nm Green 532nm Laser output 180mW 120mW 650nm 60mW 532nm Scanner system 20Kpps optical scanner Optical ang...

Page 3: ...e the device Maintenance and service operations are only to be carried out by authorized dealers Always disconnect from the mains when the device is not in use or before cleaning it 2 HEALT HAZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock Operating determinations The operator has to make sure that laser radiation also reflected laser radiation hig...

Page 4: ... shock Product Rear View FUNCTION TABLE 3 1 MIC Audio in 2 VOLUME Volume sensitive 4 Message center Indicating the state of SD card controlling system 3 SD Card Controlling Settings Used to set some important parameters for SD card 5 SD Card SD Card maximum capacity of 1 Gigabytes support 6 Mode Switch Select the operating modes 7 DMX IN DMX 512 signal input 8 DMX OUT DMX 512 signal output 9 START...

Page 5: ...witch While it is switched to OFF position the equipment works in sound auto mode While it is switched to ON position the equipment works in sound mode 1 1 Sound Auto mode When the 10th switch is OFF 1 9 are function codes Here the functions as bellows If the 1st switch is OFF the equipment works in sound mode If the 1st switch is ON the equipment works in automatic mode For master slave mode put ...

Page 6: ...ry system 0 or 1 through switch 1 9 Examples 5 DMX address DMX address 1 33 65 113 161 225 DMX base adds 1 10 setting ON is 1 OFF is 0 1 10 Function 0 0 0 0 0 0 0 0 0 0 Sound Control 1 0 0 0 0 0 0 0 0 0 Auto Mode 0 1 0 0 0 0 0 0 0 0 Auto 1 1 0 0 0 0 0 0 0 0 Number from rear x x x x x x x x x 1 DMX 512 control ...

Page 7: ...accordingly 4 Vertical Move 192 255 auto up speed up accordingly 0 127 manual horizontal 128 191 manual right speed up accordingly 5 Horizontal Move 192 255 manual left speed up accordingly 0 127 manual vertical rotation 6 Vertical Roll 128 255 auto vertical rotation speed up accordingly 0 127 manual horizontal rotation 7 Horizontal Roll 128 255 auto horizontal rotation 0 127 manual rotation 128 1...

Page 8: ...after the other 3 Up 7 Use this key to change the current number in the blinking digit The number will be increased When reaching the maximum number 9 the number will be start from zero again Example Set DMX base address to 200 Press FUNC until Adr blinks Press SEL until current value is displayed and right digit blinks Press Up until 0 is reached Press SEL to go to middle digit Press Up until 0 P...

Page 9: ...e center 8 If any error condition occurs a code will be displayed on the status LEDs see table Not all errors will cause a stop of playback Errors from the memory card read write will cause a total shutdown of the player If there is no card or the card is not inserted correctly of if there is no right format or file system the player functions will be shut down When there is no file allocated to a...

Page 10: ...s the maximum positive offset When changing this value via DMX the projected display can jump because DMX signal rate is slow Channel5 Offset Y vertical position See Offset X Channel6 Frame repeat Shows in ILDA format do not contain any timing information When all frames of a show are outputted one after the other the animation speed is too fast By repeating every frame a number of times the speed...

Page 11: ...es are created The Poseidon only reads the short names The long names need additional space in the root directory To avoid losing space and limiting maximum possible number of files the names should be kept as short as possible Short filenames are not case sensitive 2 4 3 Reserved Filenames 10 Some filenames are reserved for device control These files will be read out by the Poseidon automatically...

Page 12: ...2 Maximum sum of base address plus highest used control channel is 512 Any overflow will be watched by the software and a message will be displayed Fig 2 Global settings Setting up DMX channels Fig 3 Each parameter control can be placed to any channel starting from the base address By checking NONE DMX control can be disabled and a fixed value can be used ...

Page 13: ...ond and 1000 points per second minimum Keep in mind that changing the point output speed also will change the speed of the displayed animation and also will influence the blanking settings blank shifting For this reason the speed should be adjusted carefully When DMX control of this function is disabled the value set in the showtable individual for every show is used Framerepeat Input the channel ...

Page 14: ...ill be taken For center position use a value of 128 Offset Y vertical position See Offset X Blankshift Input the channel number corresponding to this function here This function can be controlled in 16 steps Here the timing of the blanking Laser off and the colors can be controlled Because the scanners are slower than the changes of colors or blanking these changes have to be delayed Common used v...

Page 15: ...ace all show files on the memory card and then selecting them directly from the card Note for Windows 2000 or Windows XP with NTFS file system NTFS will not create short filenames or change the names when copying files to the card It is recommended first copying all show files to the card and then select all files directly from the memory card when making configuration Speed Kpps Fig 6 14 This is ...

Page 16: ...t Loop When using this mode playback of the show will be repeated as long as no new show will be selected For example when the show only consists of one single frame this frame will be displayed permanently Oneshot The selected show will be displayed exactly one time When the show only consists of one single frame this frame will be displayed n times where n is the value under Framerepeat When pla...

Page 17: ... Note When a show is running in Complete mode all parameters like speed size offset framerepeat and blankshift will be held also when controlled by DMX Otherwise the parameters would be changed when selecting a new show during playback of the current show The Pauseshow 16 Normally the filename at show number 0 Pause is left blank When selecting Pause or after finishing playback the laser is blanke...

Page 18: ... 2 5V Green 6 0V to 2 5V X 14 Connect to ground Y 15 Connect to ground Red 18 Connect to ground Green 19 Connect to ground Ground 25 Cable shield Caution Because the device is equipped with scanner of 20Kpps so you should do tune down the setting of scan rate below 20K per second when you use software Pangolin Mamba Phoenix etc to control the device Too high scan rate will be greatly harmful to th...