Issue 3 11_2021

Night Mode

2

EL-WEM Quick Start Guide 

Wireless Indoor Air Quality Monitor

Your data, anytime, anywhere

The EL-WEM simultaneously measures 
a number of different parameters that 
affect air quality and uses them to 
calculate an overall Indoor Air  
Quality (IAQ) level. 

The colour of the status ring shows the
current IAQ level. If the IAQ is Poor or
Inadequate the status ring will turn red
and the sounder, if activated, will beep 
to alert those nearby. If you have 

configured email or SMS notifications 

on the Cloud these will automatically 
be sent to your selected recipients.

Indoor Air Quality Monitoring

5

Low Power Mode

7

Calibration Mode

(EL-WEM+ only)

8

The carbon dioxide (CO

2

) sensor in the 

EL-WEM+ is extremely accurate and to 
maintain this accuracy it should be 

calibrated every 6 months. 

First, provide as much fresh air as 

possible to the EL-WEM+, for example 
place it next to an open window. Then 
press and hold the power button for 10 
seconds; the sounder will beep and the 
status ring will turn white. 

The calibration process is automatic 
and will take a little while; when it’s 
complete the sounder will beep again 
and the EL-WEM+ will return to its 
normal monitoring mode. If for any 
reason calibration fails to complete the 
sounder will beep 
4 times at the end 
of the process. 
You should then 
ensure the supply 
of fresh air is 
adequate and 
restart calibration 
mode.

WiFi Network Features

9

The EL-WEM contains a back-up battery 
that can power the unit if mains power  
is lost. When running from the battery  
the EL-WEM goes into low power mode, 
and will upload data to the Cloud once an 

hour, although notifications for poor indoor 

air quality will be sent  immediately. It is 

not possible to enter configuration mode 

or calibration mode until mains power is 
restored. 

When your WEM is in Low Power Mode 

you may get ‘Connection Lost’ notifications 
from the Cloud (if you have set them up) as 

in Low Power Mode it doesn’t connect to 
the Cloud as frequently as normal.

The battery is intended as an emergency 
backup only and should not be used to 
power your EL-WEM for long periods. 

The battery cannot be accessed or changed 
by the user and is recharged automatically 
when mains power is restored.

Excellent

Good

Fair

Poor

Inadequate

There are five levels

Your WEM contains an alarm sounder that 

you can activate from the EasyLog Cloud, to 
give an audible warning if the IAQ level is 

Poor or Inadequate. There is also an option 
to set a time period each day when the 
status ring and sounder are turned off.

Do Not Disturb Mode

6

Connect to the Cloud 

4

Log in to the EasyLog Cloud App on your mobile device. 

Select ‘Setup Device’ and 

follow the on-screen instructions to 

configure your EL-WEM. When setup is complete the sounder 

will beep and the EL-WEM will automatically start monitoring your 
indoor air quality. 

When connected to the EasyLog Cloud, your EL-WEM will regularly upload 
data from all the air quality parameters it measures. You can then graph,  

analyse and share this data and also set automatic notifications via email    

or SMS to keep you informed at all times.

If you choose not to connect your EL-WEM to the Cloud it will still monitor indoor air 

quality levels, but it will not record data and you won’t be able to use of any of the additional 

features of the EasyLog Cloud.

1

2

3

4

After you’ve connected the EL-WEM to your WiFi network, if the power button starts flashing again it means the monitor has been 

unable to connect to the network to upload data. The EL-WEM will automatically try to reconnect, but you should also check if your 

WiFi network is available. If you want to perform an immediate upload to the Cloud and your network is available, do a short press of 
the power button. This will create an audit mark in the event record. To reconfigure the WiFi settings (e.g. to change your EL-WEM to 

use a different WiFi network), press the Setup button on the base of the unit for 3 seconds. This restarts the setup process explained 

in section 4 above.