background image

 

Instruction Manual 

Hydrostatic Test Hand Pumps WAP0070

 

 

WARRANTY 

LARZEP,  S.A.

  guarantees  its  products  against  all  design  and  manufacturing  defects  for  two  years  from  the  date  of 

purchase. This guarantee does not include the ordinary wear of both metal and non-metal parts, abuse, using the 
equipment beyond its rated capacity and any wear or damage incurred as a result of using a hydraulic fluid which is 
not recommended by 

LARZEP, S.A. 

Please note that if the equipment is disassembled or serviced by anyone other than an authorized service dealer or 
by 

LARZEP, S.A

., this guarantee is rendered null and void. 

In the event of a warranty claim, return the equipment to 

LARZEP, S.A

. or the authorized dealer which sold you the 

hydraulic  equipment. 

LARZEP,  S.A

.  will  repair  or  replace  the  faulty  equipment,  whichever  is  deemed  most 

appropriate. 

LARZEP,  S.A.

  shall  not  be  held  liable  for  any  consequential  damages  or  losses,  which  may  occur  as  a 

result of faulty equipment. 

 

 

BEFORE USING THE EQUIPMENT AND ESSENTIAL SAFETY REQUIREMENTS 

-

 

Hydraulic  test  pumps WAP0070  is  designed  for  testing  the tightness  of  boilers, pipework,  pressure  reservoirs,… 
that are under pressure during standard operations. 

-

 

All pumps are tested individually. 

-

 

Read the instruction manual carefully and practise using the equipment before application. 

-

 

Always use protective goggles, safety shoes and protective gloves. 

-

 

The pump body is supplied fitted to the tank by screws. The pump is supplied with a suction pipe (3/8”) in the 
lower part and with a stainless steel filter to prevent entering solid parts or impurity.  

-

 

Assembly all components. Pressure gauge and coil are supplied. Make sure that all parts are properly tightened. 

-

 

Use PTFE (Teflon) tape or in liquid or fillets paste on all threads to prevent any leakage. 

-

 

Do not modify the device (welded parts, lengthening drive levers, etc.). 

-

 

Avoid dangerous environment influences (i.e. inflammable fluids or gases). 

-

 

Place the equipment on a flat and solid area with adequate lighting. 

-

 

Never  exceed  the  maximum  working  pressure  of  the  pump.  Ensure  that  all  the  equipment  and  accessories  are 
suitable for the maximum working pressure. 

-

 

In all cases, the operator should have received adequate training regarding the handling of the device and logical 
safety criteria. 

 

TECHNICAL FEATURES 

 

 

 

Model 

Working 
Pressure 

Flow / 
Stroke 

Outlet 

Port 

Capacity  Weight 

LARZEP 

bar 

cc 

BSP 

litres 

kg 

WAP0070 

70 

11 

1/2" 

Female 

13 