Instruction Manual 

Hydrostatic test hand pumps WAP0025, WAP0045, WAP0050, WAP0100

 

 

ASSEMBLY AND OPERATING  INSTRUCTIONS 

The components are shipped unassembled to prevent breakage or unnecessary bulk during transport or the stockage 
in warehouse. 

 

 

The  pump  is  provided  with  pressure  gauge,  coil  and  double  control  valve.  On  demand,  we  can  provide  a  delivery 
flexible hose, designed to withstand the pressure rating. 

Assemble the device in accordance with the next procedure, first checking that you have all the necessary material. 
Use PTFE tape on all threads. 

Before starting any operation, clean the tank to eliminate any residue or waste. 

1.

 

 Screw suction pipe into the base of the pump. 

2.

 

 Assembly the pump on the bridge of the tank. 

3.

 

 Screw in the valve unit, ensuring the connection hole for the gauge tube is opposite the outlet and is vertical. 

4.

 

 Screw the gauge tube and mount the gauge. In order to favour the immediate reading during the test, point 

the pressure gauge in the direction of the operator. Remember to apply necessary seals to all components. 

5.

 

 Check that all connections are tightened and connect the pump to the tank using the supplied screws. 

6.

 

 Fill up the tank and ensure the suction tube is completely submerged. Use anticorrosive, antioxidant fluid or a 

mixture of water and emulsifiable oil in order to prevent oxide formation inside the machine.  

7.

 

 Connect the hose. 

8.

 

 Connect the pump to the system or equipment. 

9.

 

 Before  operating  the  pump  always  make  sure  pipe  connections  are  clean  and  fully  tightened  up;  all 

accessories have been fitted correctly: suction tube with nut and filter, pressure gauge and delivery hose for 
high pressure (not included). 

Always use protective goggles, shoes and gloves.

 

10.

 

 Pre‐fill the system or equipment before starting the test with the same liquid that will be used for testing. 

11.

 

 To  start  the  test,  close  the  discharge  valve  (left)  and  open  the  flow‐valve  (right)  manually.  There  are  two 

handwheels on the control valve block for these two valves

 

12.

 

 Now pump using the drive lever. The pump will come into operation taking the fluid from the tank below and 

sending it to the system or equipment to be tested. 

13.

 

 Continue pumping to increase the pressure on the system. 

14.

 

 Check the pressure shown in the gauge and do not exceed the maximum pressure. 

15.

 

 Once  reached  the  required  pressure,  close  the  flow‐valve,  handwheel  on  the  right,  to  maintain  the  same 

pressure value in the element under pressure. Make sure there are no leaks. 

16.

 

 

To finish the operation, open both valves and surplus liquid will run back into the tank via the drain hole in the 

valve control block. 

17.

 

 To perform another test, follow the instructions from the beginning. 

18.

 

 Replace the seals at least every two years. 

19.

 

 If  antioxidant additives are not used,  is  recommended  to  empty  the tank  every  time  is  planned  a  period of 

inactivity. 

 

 

 
 

The pump must always be handled and repaired by qualified personnel.

 

Ensure that all the equipment and accessories are suitable  

for the maximum working pressure. 