Operating in this mode will recharge the light’s internal battery. 

NOTICE: 

Because the light DC accessory receptacle is connected directly to the internal battery, 

when not using this external source option, you can plug any accessory up to 8 amps, (i.e. laptops, 
cell phone chargers of the light hand held units), into the receptacle and the light will provide power. 
If the amperage rating is exceeded, a built in auto-reset circuit breaker automatically shuts power off 
until the accessory overload is removed. 

 

TO DISCONNECT AFTER USE:

 

1. 

Switch lights off. 

2. 

Turn vehicle ignition off. 

3. 

Disconnect the dual end DC power cord from the vehicle. 

4. 

Disconnect the dual end DC power cord from the light by twisting the plug away from the lock 
arrows and pulling. 

 

UTILIZING AC POWER

 

  The light is equipped with a power receptacle located on the right hand side of the case. 

  It can operate on either 110/240 Volt, 50/60 Hz power. 

  This power receptacle is used for recharging the internal battery. 

  It can also be used as a supplemental power source to the internal battery. 

 

TO UTILIZE THIS AC INPUT OPTION

 

1. 

The “EXTERNAL INPUT/OUTPUT” switch should be switched to the off position. 

2. 

Plug the side of the power cord into the power receptacle on the light. 

3. 

Plug the other end into an AC wall outlet. 

4. 

Turn the lights on. 

5. 

When the internal battery has been depleted, the lights should be switched off and the unit 
recharged or utilize one of the before mentioned external DC power input methods for 
continued operation. 

 

TO DISCONNECT AFTER USE

 

1. 

Turn the lights off. 

2. 

Unplug the AC power cord from the AC wall outlet. 

3. 

Unplug the AC power cord from the socket. 

4. 

Recharge the light using AC power. 

 

RECHARGE USING AC WALL OUTLET

 

1. 

The “EXTERNAL INPUT/OUTPUT” switch should be in the off position. 

2. 

Plug the side of the power cord into the power receptacle on the light. 

3. 

Plug the other end into an AC wall outlet. Recharging time is a factor of DoD. 

4. 

It is recommended that the unit be charged at least 4 hours to condition the battery for next use.  

 

NOTICE: 

The light is equipped with a digital DC volt meter that operates when the light is turned on. This 

will display the current voltage level of the internal battery.  

 
 
 