Dip Switches 

The following settings can be adjusted with the dip switches on top of the unit. Be sure to power off the unit before 

making any changes in order for these settings to take effect. 

Primary Timer Operations

Reset: 

Long press "R" until it reboots.

Unlock Timer:

 

Press the "CIR" four times, and the "a" will disappear in the screen. All of the keys are valid to press. If the keys aren't be 

pressed within 30 seconds, they will be automatically locked.  

Set current time:

 

Press 

"WEEK"

 to select current day of week Press 

"HOUR"

 and 

"MIN"

 to select current Hour and Minute.

Program timer:

 

For an example, you want to tum on at 6:00(6AM) and tum off at 20:00(8PM) 

1. Press 

"P"

 and 

"I ON-:-"

 will display

2. Then press 

"WEEK"

 to select day(s) of week

3. Press 

"HOUR"

 and 

"MIN"

 respectively to select Hour and Minute, 

"I ON 6:00"

 will display

4. Press 

"P"

 and 

"I OFF--:--"

 will display

5. Then press 

"WEEK"

 to select day(s) of week

6. Press 

"HOUR"

 and 

"MIN"

 respectively to select Hour and Minute, 

"I OFF 20:00"

 will display Note: 

"MO TU WE TH

FR SA SU"

 for 

"Monday Tuesday Wednesday Thursday Friday Saturday Sunday"

*Repeat the steps above to set more programs.

NOTE: 

Each "ON" requires "OFF". Be careful that programs do not overlap or conflict with each other, or timer

will not perform as expected.

Cancel/Recover functions: 

Press 

"CIR"

 to cancel or recover the setting. Attention: When the time is 

"- - : - - "

, it means that the setting is being 

cancelled. When it is 

"00: 00"

, it means 12AM.

 

Manual override: 

Select mode, 

"Auto"

 or 

"ON" 

or 

"OFF"

"Auto"

 for timer functions. 

BLACK INDICATES DIP SWITCH

 

Sensitivity

 

Adjusts the sensitivity of the motion sensor. 

2 meters (6.5ft)

 

5 meters (16ft)

 

8 meters (26ft)

 

10 meters (33ft)

 

Time-Delay

 

Sets the on-time of the motion sensor. 

10 seconds 

15 minutes

 

20 minutes

 

25 minutes

 

1 minute 

5 minutes 

10 minutes 

30 minutes

 

Light Intensity Setting 

Adjusts the output level. 

24H 

100 LUX

 

200 LUX

 

300 LUX

 

10 LUX 

20 LUX 

50 LUX 

500 LUX

 