WIRING 
Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

20V  and  240V

 AC, 

or 

60Hz

.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

DETACHABLE CORDS

Cord is attached via a weatherproof 2-pin Deutsch connector.

The  cord  is  detachable  by depressing  the  tab  on  the  top  of  the  connectors.  This  enables the

operator to remove and store the light while leaving the cord connected to the power source.

Additional or replacement cords can be ordered from our website. Contact us or visit LarsonElectronics.com for more

information.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

FRL-EMX-18-90W-FUVC-KT

 is designed to provide years of reliable performance. Should the need for replacement 

parts arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Reviews: