EXPCMR-WIP-RPS-OZ-2MP-BC

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

4

 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. IF WIRING OR 

UNIT

 REPLACEMENT 

INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, THE 

FIXTURE

 MAY NOT BE SUITABLE FOR THE HAZARDOUS LOCATION INVOLVED. 

WHEN HANDLAMP IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE MUST BE 

SUITABLE FOR HAZARDOUS LOCATION INVOLVED. WHEN 

FIXTURE

 IS CONNECTED TO POWER SOURCES OUTSIDE OF HAZARDOUS 

AREA, STANDARD DUTY PLUGS AND RECEPTACLES MAY BE USED.  

STANDARD PLUG AND TRANSFORMER MUST ONLY BE CONNECTED TO A RECEPTACLE LOCATED OUTSIDE THE 

HAZARDOUS AREA! 

IMPROPER USE OF THIS 

FIXTURE

, ASSOCIATED PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE 

FIXTURE

 AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, THE CORD MUST 

BE REPLACED BEFORE RESUMING USE OF THE HANDLAMP.  

THE GLOBE IS MADE OF TEMPERED GLASS. IF THIS GLASS BECOMES SCRATCHED OR CHIPPED IT SHOULD BE REPLACED IMMEDIATELY. 

The EXPCMR-WIP-RPS-OZ-2MP-BC from Larson Electronics is an Explosion Proof Outdoor Security Camera for 

flammable work sites, harsh environments and outdoor locations. This IP66-rated device is rechargeable and offers 

wireless video output and connection to other devices. Capable of producing clear, 1080p HD images, the unit features an 

adjustable rail mounting system for versatile applications around the work site.

WIRING 
Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 

12V DC

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Exp Cord Cap 

Position  device  near  work  area  for  operation.  Run  cable  to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle within 

the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

receptacle face. Insert plug straight all the way into receptacle until it

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

completes circuit. This also mechanically locks plug into receptacle so it

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

straight out.

Low Voltage DC 

Connect  power  to  power  supply  outputting  low  voltage 

at  12

  Volts  DC.  This 

variable  voltage  allows  greater  versatility  without  affecting  light  output.  Ensure 

deutsch connectors are properly connected (If applicable) 

Reviews: