TO CHARGE BATTERY
1.
Do not charge in a hazardous atmosphere.
2.
Plug the AC adapter into 120 VAC power outlet.
3.
Be sure that the selection switch in the top left corner of charger is set to 1.8A.
4.
Plug charger DC jack into top of battery DC jack.
5.
LED indicator light on charger will turn Red during charging.
6.
Indicator light on charger will turn Green when fully charged.
7.
When charged, disconnect from AC power outlet.
8.
CAUTION:
Extensive overcharging will affect the normal performance and service life of the
battery.
CAUTION
Do not shine light directly into eyes.
Inspect regularly for damage and repair or replace if necessary.
If battery pack is cracked or damaged –DO NOT USE – Replace the battery pack immediately.
Do not submerge in liquids.
Do not use charger is hazardous atmospheres.
Battery pack may be replaced in hazardous atmospheres.
Use only replacement battery pack specified.
Use only charger provided.
Dispose of spent battery packs in accordance with local and Federal laws.
HAZARDOUS LOCATION LISTINGS
Class I
-
Flammable Gases, Vapors or Liquids
Division I
-
Where ignitable concentrations can exist all of the time
Groups
- C
- ethylene
D- propane
Temperature Code T3 ≤ 200° C
NOTE:
Do not use in other hazardous areas.