background image

EPL-WPLED-150W-RT-140DB

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

2

 of 

4

 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. IF WIRING OR LAMP REPLACEMENT 

INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, THE HANDLAMP MAY NOT BE SUITABLE FOR THE HAZARDOUS LOCATION INVOLVED. 

WHEN HANDLAMP IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE MUST BE SUITABLE 

FOR HAZARDOUS LOCATION INVOLVED. WHEN HANDLAMP IS CONNECTED TO POWER SOURCES OUTSIDE OF HAZARDOUS AREA, 

STANDARD DUTY PLUGS AND RECEPTACLES MAY BE USED.  

STANDARD PLUG AND TRANSFORMER MUST ONLY BE CONNECTED TO A RECEPTACLE LOCATED OUTSIDE THE 

HAZARDOUS AREA! 

IMPROPER USE OF THIS HANDLAMP, ASSOCIATED PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO 

PERSONNEL. 

PERIODIC INSPECTION OF THE HANDLAMP AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND, THE CORD MUST 

BE REPLACED BEFORE RESUMING USE OF THE HANDLAMP.  

THE GLOBE IS MADE OF TEMPERED GLASS. IF THIS GLASS BECOMES SCRATCHED OR CHIPPED IT SHOULD BE REPLACED IMMEDIATELY. 

The Larson Electronics EPL-WPLED-150W-RT-140DB Explosion Proof LED Wall Pack Light fixture provides operators 

with a powerful and energy efficient alternative to traditional hazardous location luminaries. Cree LED technology and 

compact design makes this lamp an excellent replacement upgrade option for bulky and high maintenance cost older 

fixtures.

WIRING 
Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 100V  -  277V AC, 50 or 60Hz 

except those factory ordered with low voltage 11V to 25V AC/DC. 

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This unit comes pre-wired from factory with the selected cord cap. Take 

precautionary steps for weatherproofing all connections if installed in a 

location where water may come in contact with the unit. All outdoor 

installations and indoor installations near a wet location require the use of a 

GFCI  device for safety, according to the National  Electrical  Code® (NEC). 

Ensure the unit is properly grounded. 

For supply connections, use wire rated for at least 110°C 

MOUNTING 

This fixture offers an adjustable surface mounting system that allows this fixture to be mounted to any flat surface including 
walls and ceilings. A single ½-13 bolt is used to mount the fixture to the surface. 

1.

Using bolts, washers and nuts provided, attach brackets “A” to both sides of
bracket “B”.

2.

The LED fixture has 9 holes for a versatile mount option. Select the holes that you would like

 

to use.

3.

Brackets “A” will then be bolted to the LED fixture with the remaining bolts and washers.

4.

The fixture is now ready for installation.