EPL-RPS-70A

Larson Electronics, LLC

 

Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

1 of 2 

Portable Explosion Proof Power Supply - (4) 12/24 Volt DC Class I 

Division 1 Outlets - Rechargeable

 Instruction Manual 

The Larson Electronics EPL-RPS-70A explosion proof power supply enables operators to power low voltage LED lights via four Class 

1 and 2, Division 1 and 2 receptacles. 

This explosion proof transformer system is rated at 1KVA. Do not attempt installation or 

operation until you are familiar with all warnings, precautions, and procedures outlined within this document. 

Safety Warnings

 

 For personal safety, always follow the safety instructions in this manual to ensure safe and long- 
term use. Failing to do so can result in damage to the product or serious bodily injury. 

WARNING 

DO NOT 

place in a location where the power substation has the potential to roll or tip over. 

DO NOT

 perform maintenance while energized.

 

DO NOT 

stand under power substation while elevated for transport. 

DO NOT 

use this product for other than its intended use. 

DO NOT 

open or modify power substation. 

Always ensure a clear area while maneuvering power substation.

 

 

   WARNING: 

Electrical potentials hazardous to human life can exist within this equipment when energized. Disconnect all input power before 
opening case or touching internal parts. Use proper lock-out/tag-out procedures. 

The information contained herein may not cover all variations in equipment or provide for all contingencies which might be met in 
installation, operation and maintenance. 

Failure to follow instructions may result in death or serious injury 

Inspection upon Receiving 

Power distribution should be carefully inspected upon receipt to ensure that no damage has occurred during shipment. Any damage 
should be reported at once and a claim should be placed against the shipping company. 

   WARNING: 

Only qualified personnel should install, inspect, or maintain transformers since the normal operating voltages can be hazardous. 
Do not place combustible materials on or near transformer or mount transformer closer than 6 inches from any adjacent wall. 
The nameplate rating on the unit should be checked against the job specifications to ensure installation of the correct transformer. 

Power distribution substation should never be operated without access covers securely mounted in place. 
A safety program must be established, verified and followed by all personnel involved with the power distribution unit. 

OPERATION:

 

Place the cart on a level surface near a power source. The 

power supply

 provides multiple options for 

maneuvering. These vary upon model purchased: 

Tires 

Roll around on ground surface. maneuver like a traditional dolly cart. Tilt

 

cart by handle 

toward you and roll to the desired location.

Center Lift Point

 Lift with sling cable via crane or similar.

 

Use equipment

 

capable of lifting 

2000lbs. minimum.

The  EPL-RPS-70A  explosion  proof  portable  power  supply  is  built  to  provide  operators  in  hazardous 

locations with a method of power low voltage hand lamps with 12 or 24 volts DC output. This unit includes 

four  explosion  proof  receptacles  rated  at  20  amps  each.  This  compact  power  distribution  system  is 

designed for portability and convenience as well as durability and is mounted to a wheeled, non-sparking 

aluminum frame for added protection.

The  explosion  proof  enclosure  contains  a  70ah  AGM  battery  and  charger/maintainer  systems.  This 

explosion proof battery system comes standard with a 25 foot, 16/3 SOOW cord terminated with a 120V, 15 

amp explosion  proof male plug. The EPL-RPS-70A is designed  to be charged  within Class 1 Division  1 

classified areas.

Once the encapsulated 70ah sealed lead acid battery is depleted, operators can plug this unit into an 

explosion proof 120 volt outlet or standard 120 volt outlet to charge the unit overnight within the hazardous 

location.

RECEPTACLE OPERATION 

Electrical connection between explosion proof receptacles and plug is accomplished after plug fully inserts 
into receptacle and rotated clockwise. 

*NOTE: PICTURES SHOWN MAY VARY.

RUN FLAT TIRES 