Warning: Check product label for correct voltage!
Position device near work area for operation. Run cable to nearby power source. Insert and twist-lock explosion-
proof plug into a compatible receptacle
outputting correct voltage
within the hazardous environment. See
plug operation
below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished after plug fully inserts into receptacle
and
is
rotated clockwise.
1.
Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug
straight all the way into receptacle until it
cannot go further.
2.
Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also
mechanically locks plug into receptacle so it
cannot be pulled out.
3.
To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light and allow the unit to cool down before
performing maintenance.
1.
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a yearly basis. Frequency of use and environment should determine this. It is
recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.
2.
The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.
3.
Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.
4.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
5.
Fixture is field serviceable by a licensed electrician, and all major parts are available from Larson
Electronics.
Light Head Adjustment
Once the light is mounted in the desired location, the angle of the light head
itself can be adjusted to achieve maximum lighting efficacy. Simply loosen the
two T-handle adjustment screws on either side of the light, tilt the light head into
the desired position, and re-tighten the T-handle screws to hold it in place.
Power
T-handle
Adjustment
Screw
Once the light is mounted in the desired position, you are now ready to power on the light. Be sure explosion proof plug is
being mated with compatible explosion proof receptacle within the hazardous area, and follow all applicable local and
national electrical codes.