3.

Brackets “A” will then be bolted to the LED fixture with the remaining bolts and washers.

4.

The fixture is now ready for installation.

WIRING 

(see attached wiring diagram)

 

This unit comes preconfigured with the selected cord cap. Run cable from light and connect to matching 
receptacle outputting the correct voltage. Follow all applicable local, state, and National Electrical Code for the 
hazardous area! 

 
 
 
 

RECEPTACLE/PLUG OPERATION

Electrical connection between receptacle and plug is accomplished after plug fully inserts into receptacle and 
rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and receptacle face. Insert plug straight
all the way into receptacle until it cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and completes circuit. This also
mechanically locks plug into receptacle so it cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug straight out.

MAINTENANCE

 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine
checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is
recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:
Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.
Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid
cleaner.

3.

Inspect the cooking fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

 

WARNING:

 CHECK NAMEPLATE 

FOR PROPER VOLTAGE. DAMAGE 
FROM IMPROPER VOLTAGE WILL 
VOID WARRANTY. 

Brackets “A”

Bracket “B” 

Trunnion Bracket 

Reviews: