background image

EPL-FL1524-50-1523

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

3

 of 

4

 

INTRODUCTION 

This document covers the operation, maintenance, and

 

re-lamping procedures for an 

EPL-FL1524-50-1523

 

series hazardous location work light. 

This light is suitable for the following hazardous locations 
only: 

Class I, Divisions 1, Group

s C,

 D 

Class II, Divisions 1, Groups E, F, and G 
Class III, Divisions 1

Refer to the National Electric Code (NEC) NFPA 70 for 
more information on hazardous locations. 

The 

EPL-FL1524-50-1523

 work light runs on the voltage 

specified on product label. Check that the light being 
used matches this criteria for operation. Be sure that the 
line has appropriate termination and is grounded properly. 

WARNING:

 Non-Explosion proof cord caps 

MUST 

ONLY

 be used 

OUTSIDE

 

HAZARDOUS AREA!

 

Run cable and non-explosion proof cord cap outside 
hazardous area for powering the light. With standard 
non-explosion proof cord caps, only the Drop Light is 
rated for use in HAZARDOUS areas. 

MAINTENANCE: 
WARNING:

 It is very important that only qualified 

personnel perform maintenance and repair operations in 
a NON-HAZARDOUS area. The integrity of the 
component assembly and flame-path must be 
maintained in order to provide adequate protection for 
personnel using this light. Comply with all NEC Rules 
and Regulations when performing maintenance 
operations. Failure to comply with these could result in 
an explosion, electrical shock, or personal injury. 

CLEANING: 
WARNING:

 DO NOT use any solvent or cleanser that 

contains alcohol, hydrocarbons, or has potential to 
cause an explosion. Using this type of cleanser could 
cause an explosion or serious personal injury. 

CAUTION:

 Clean external parts of work light only; 

internal parts do not require cleaning. Applying solvent 
could result in damage to the electrical equipment. 

The 

EPL-FL1524-50-1523

 can be cleaned by applying 

Simple Green® or an equivalent cleanser and wiping 
any dust or grease off with a rag. After cleaning process 
is performed, allow adequate time for light to completely 
dry before placing in operation. 

WARNING: 

When performing maintenance operations 

disconnect power. Failure to do so could result in 
electrical shock. 

USAGE INSPECTION:

 Prior to each use make a 

thorough visual inspection of the work light for any chips, 
cracks, or burns within the glass, aluminum handle, and 
cage. Check the entire length of the cord for any frays or 
visible wires that could affect the performance of the 
light. Check that all the rubber bumpers are integral with 
the aluminum. If there are any frays in the cord, cracks in 
the glass or disturbances in the aluminum outside of 
normal wear, remove the light from service immediately 
and contact Larson Electronics. 

TO REPLACE A LAMP OR STARTER:  
WARNING: 

When re-lamping work light, disconnect 

power. Failure to do so could result in electrical shock. 

1.

Remove four bolts on handle with Allen Head
Wrench

2.

Pull cap gently and evenly outward

3.

Wiring, starter, and tube should slide out

4.

Replace necessary parts

5.

Check “O” Ring - must be in good condition

6.

Slide assembly back into handle and tube

7.

Fasten securely with 4 bolts.

8.

Test in non-hazardous location before using in
hazardous location to ensure proper operation of
light.

Reviews: