background image

Ver.0918-1 

EPL-24-2L-LV-SOL-80C-C1D2-20C

Larson Electronics LLC 

Thank  you  for  purchasing  the  Larson  Electronics 

EPL-24-2L-LV-

SOL-80C-C1D2-20C

 

solar powered LED  light. Follow the  steps below for 

installing and maintaining your unit. 

IMPORTANT 

READ CAREFULLY BEFORE OPERATING THIS LIGHT. SAVE THESE INSTRUCTIONS 
FOR FUTURE REFERENCE. 

THIS FIXTURE SHOULD BE INSTALLED BY QUALIFIED TECHNICIANS IN STRICT 
ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ANY LOCAL 
REQUIREMENTS. 

WARNING: 

IF  UNSURE ABOUT ANY SECTION OF THESE INSTRUCTIONS, CONSULT 

A QUALIFIED PROFESSIONAL TO INSTALL THIS DEVICE. 

WARNING:

 

DEVICE IS SUITABLE FOR INSTALLATION IN WET LOCATIONS.

 

WARNING:

 

ALTHOUGH WATERPROOF, ANY PART OF THIS UNIT IS  NOT DESIGNED 

OR INTENDED TO BE SUBMERGED.

 

WARNING:

 

DO NOT ALLOW DETACHABLE WIRES TO BECOME SUBMERGED!

 

IF DROPPED OR DAMAGED, THE UNIT MAY NO LONGER BE WATERPROOF AND 
SHOULD BE REPLACED. 

HOW SOLAR LIGHT WORKS 

Solar light must be placed outdoors. The solar panel collects and converts sunlight 
into DC power while the pre-installed rechargeable batteries store the energy to 
power the light at night.  

Solar light illumination time 

It depends on the seasonal sunlight availability in your geographical area under 
certain weather conditions. Stronger or longer sunlight hours enable batteries to 
store more energy which provides more lighting hours. On the contrary, weaker or 
shorter sunlight hours reduce the lighting hours and its brightness as well. 

Solar panel mounting locations 

Solar panel must be placed outdoor at a location with its solar panel receiving direct 
sunlight at least five hours each day. Shadowed locations will not allow batteries to 
be fully charged and will reduce both the brightness of the light and the lighting 
hours. Precautions (prior to first time use) 

1.

To maximize battery capacity, the solar panel should be fully charged by
direct sunlight for five hours before initial use.

2.

Under extremely cold temperatures, the batteries may not charge fully. In
such cases, the Solar Lights may not stay illuminated as long.

MOUNTING SOLAR PANEL

This solar panel includes a permanent mounting system that allows for mounting to 
square/round poles or flat surfaces such as a wall or post shown in figure 1.  

Position the solar panel in a location that receives the maximum amount of sunlight 
throughout the day. This may need adjusted depending on the season. With pole 
mounting, loosen the adjustment bolts to fit solar panel onto pole. Once mounted, 
tighten bolts snug to secure panel to pole. For surface mounting, remove additional 
plate and use the existing mounting holes to mount directly to surface. 

MOUNTING 

The light is connected to the 
panel by cord. Be sure the 
light  is connected to the 
solar panel and that the 
deutsch connections are 
tight. Run the cord and 
mount the light nearby.  

LAMP INSTALLATION 

PRECAUTIONS 

Do not install fixture in any classified location where the marked
operating temperature exceeds the ignition temperature of the hazardous
atmospheres.

Consult fixture nameplate for the suitability ambient temperature shown on
the nameplate.

Refer to fixture nameplate for minimum supply wire temperature rating.

Verify that the supply voltage agrees with fixture rating as indicated on
nameplate.

All local and national electrical/building codes must be followed

when installing this lighting fixture. For code interpretation, consult

your local authority.

Product must be used only with glass tubes intact and all cap threads
fully engaged. Do not use if glass tubes are cracked or damaged.

Caution: 

Only use lamp size, type and /or wattage as shown on fixture nameplate. 

We strongly recommend that only a licensed electrician install this product.

 

WARNING: 

Make sure that the power is disconnected before installing. This fixture 

is heavy and must be mounted to a surface that can structurally support the load. 

NOTE: 

This fixture requires a minimum of 50 inches of clearance from re-lamp end 

for lamp replacement. An optional drop mounting kit that will allow for end to end 
row mounting is available, please consult factory. 

WARNING: 

Do not let fixture hang on one bracket at any time. Failing to 

comply can result in breakage of end casting or mounting bracket, allowing 
the fixture to fall, which can cause serious injury or death. 

The mounting brackets are shipped installed on the fixture.

Install the brackets to wall or ceiling with two 3/8" bolts (not supplied) at
center measurements.

Fixture is now ready for mounting.

Operation Guide 

DEUTSCH CONNECTION 

Reviews: