background image

EPF-FM-30-50C

Larson Electronics, LLC

 

  Phone: 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

2

 of 

2

 

MOUNTING

The fan includes 

an aluminum frame floor mount

, pre-installed from factory.

 In some cases, the fan will be 

removed from the base for shipping.

 This requires the fan be re-installed to the base before operation. 

Mounting hardware will be attached to the mounting plate on the base. Remove the hardware to expose the 

mounting holes. We recommend having 2 people complete the installation of the fan onto the base, as it can 

be heavy and awkward to hold while installing the mounting hardware. Align the holes in the mounting bracket 

on the fan to the holes in the mounting plate on the base, then re-install the mounting hardware and secure 

the fan tightly to the base.

Place the fan in the desired location and run 

power cord to compatible receptacle. Fan should be placed on a 

flat surface, and can be permanently mounted with user provided hardware through holes in the base of the 

mount

if so desired. 

Ensure all safety requirements are followed for the hazardous area. 

The fan head can be adjusted by loosening the 

hardware at the adjustment point, tilting to desired angle, and 

tightening hardware back down to hold the fan head in place. 

LUBRICATION 

This motor is equipped with pre-lubricated ball bearings. The original supply of lubricant is kept free of dirt, grit 
or outside contamination by the bearing closures and does not require replenishment for the life of the bearing 
under normal operating conditions.

MAINTENANCE 

It is recommended that you implement a standard monthly or more frequent preventive maintenance 
schedule. Safety requires a thorough visual examination of the unit for physical damage that might cause a 
spark or result in the ignition of hazardous atmospheres. 

Maintenance includes a careful examination to ensure at least: 

A.

The Cable is not frayed and is gripping tightly in all points of cable contact.

B.

The Cable Jacket is completely intact and that no internal conductors or conductor insulation
is exposed.

C.

The Connection Box is not cracked, broken or breeched.

D.

The Cord Plug is not cracked or damaged and the Ground Post is intact.

Keeping blades clean and free of material splatter, overspray, and debris during usage will ensure the 
maximum life of the fan. An accumulation of dirt may cause blade vibration and motor overload. Occasionally 
check tightness of blade set screws. 

NOTE:

 Handle the propeller carefully as it is factory balanced and aligned to ensure smooth operation. 

TROUBLESHOOTING 

Refer to the guide below or contact the manufacturer if the fixture does not function properly. 

Is the correct line voltage being supplied?

Is the fan properly grounded?

Make sure installed power switch is functioning properly (if applicable).

These instructions may not cover all details or variations of this product for your equipment or installation 
requirements. Should further information not covered by these instructions be required, please contact Larson 
Electronics at 1-

 for further assistance. 

Please visit LarsonElectronics.com for 

Warranty

 and 

Return

 information.

(877) 348-9680

877-348-9680

Reviews: