8
)
The maximum number of the LED PSUs that can be connected to a circuit breaker at 230V is shown as below.
HLG-480H
0
1
1
2
3
5
Model
B10
B16
C10
C16
D10
D16
Warning / Caution !!
(1)
Risk of electrical shock and energy hazard. All
failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)
Risk of irreparable damage. LED power supplies with IP64 to IP66 rating or IP67 rating with ADJ. function must
be located indoors or in a location where these units can be sheltered from the rain if outdoors. All products
cannot be in water.
(3)
Please do not install LED power supplies in places with high ambient temperature or close to fire source.
Please refer to the specifications about the maximum ambient temperature limitations.
(4)
Output current and output wattage must not exceed the rated values on
the specifications.
(5)
The FG ( ) must be well connected to PE(protective earth) if the unit equips with it.
(6)
All PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure,
when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
(7)
If the external flexible cable or cord of this switching power supply is damaged, it shall be exclusively replaced
by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
(8)
This device complies with Part 15
of the FCC Rules. Operation is subject to the following two conditions:
(a)
This device may not cause harmful interference, and
(b)
Th
is device must accept any interference received, including interference that may cause undesired
operation.
(9)
Please install LPF series with fireproof enclosure of V1 or higher to connect peripheral equipment for BSMI
certification.