This unit is equipped with 100 feet of 600V SO cable leading to an encapsulated step down transformer. There 

is two feet of 600V SO cable coming out of the inline transformer, and is terminated in a 14W47 cord cap. This 

inline power supply for this LED blasting light is an auto sensing universal voltage transformer that operates on 

any voltage within the 100-277 volts AC 50/60Hz range. This unit allows operators to power the LED blasting 

light from any 120-277V AC power source, and steps down AC voltage to 24V DC.

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

2

0V  -  277V AC, 50 or 60Hz

.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This unit comes pre-wired from factory with the selected cord cap. Take 

precautionary steps for weatherproofing all connections if installed in a 

location where water may come in contact with the unit. All outdoor 

installations and indoor installations near a wet location require the use of a 

GFCI  device for safety, according to the National  Electrical  Code® (NEC). 

Ensure the unit is properly grounded. 

VOLTAGE

These units are able to monitor and adjust input current to maintain the correct LED voltage levels regardless of input levels 

across a specific range. This particular blasting light is fitted with our DCP-11-DP-HD encapsulated inline transformer 

terminated in a 15 amp Leviton 14W47 wet guard plug which allows operators to simply plug the unit into any standard wall 

outlet equipped with 120-277VAC.

LIGHT ADJUSTMENT 

The light can adjust up or down by loosening the allen screw in the center 
of  the  light  base.  Loosen  the screw  to  move  the  light  up  or  down  and 
tighten  when  complete.  Tighten  all  screws  once  desired  position  is 
achieved.

  

Light  can  be  easily  readjusted  by  lifting  off  the  metal  surface  and  re-
attaching to the desired position on the magnetic surface. 

MAINTENANCE 

If the lens becomes dirty, wipe down with a mild soap and water solution. 

It is recommended to occasionally inspect the unit for any defects and to ensure the cable is not frayed and is 
gripping tightly in all points of cable contact.  

TROUBLESHOOTING 

Refer to the guide below or contact the manufacturer if the fixture does not function properly. 

Is the correct line voltage supplied?

Is the line active?

Are all Deutsch connecter properly attached?