BL24-LED-600V-100-HD
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
3
of
4
This unit is equipped with 100 feet of 600V SO cable leading to an encapsulated step down transformer. There
is two feet of 600V SO cable coming out of the inline transformer, and is terminated in a 14W47 cord cap. This
inline power supply for this LED blasting light is an auto sensing universal voltage transformer that operates on
any voltage within the 100-277 volts AC 50/60Hz range. This unit allows operators to power the LED blasting
light from any 120-277V AC power source, and steps down AC voltage to 24V DC.
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor areas
where weatherproofing may be required. Universal voltage driver permits operation at 1
2
0V - 277V AC, 50 or 60Hz
.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Standard Cord Cap
This unit comes pre-wired from factory with the selected cord cap. Take
precautionary steps for weatherproofing all connections if installed in a
location where water may come in contact with the unit. All outdoor
installations and indoor installations near a wet location require the use of a
GFCI device for safety, according to the National Electrical Code® (NEC).
Ensure the unit is properly grounded.
VOLTAGE
These units are able to monitor and adjust input current to maintain the correct LED voltage levels regardless of input levels
across a specific range. This particular blasting light is fitted with our DCP-11-DP-HD encapsulated inline transformer
terminated in a 15 amp Leviton 14W47 wet guard plug which allows operators to simply plug the unit into any standard wall
outlet equipped with 120-277VAC.
LIGHT ADJUSTMENT
The light can adjust up or down by loosening the allen screw in the center
of the light base. Loosen the screw to move the light up or down and
tighten when complete. Tighten all screws once desired position is
achieved.
Light can be easily readjusted by lifting off the metal surface and re-
attaching to the desired position on the magnetic surface.
MAINTENANCE
If the lens becomes dirty, wipe down with a mild soap and water solution.
It is recommended to occasionally inspect the unit for any defects and to ensure the cable is not frayed and is
gripping tightly in all points of cable contact.
TROUBLESHOOTING
Refer to the guide below or contact the manufacturer if the fixture does not function properly.
Is the correct line voltage supplied?
Are all Deutsch connecter properly attached?