Larsen & Brusgaard
LogTrackII Operating manual
10. Start / Stop logging
The LogTrackII can begin logging automatically or manually. The LogTrackII can handle up
to 100 separate log files up to a total of 8 hours of logs.
When downloading into the LogTrackII Data Analysis software, each log is created with a
filename including Date, Time and Device ID.
Automatic Start and Stop:
If the start logging trigger altitude are not 0, the LogTrackII will automatically start and
stop logging at the preset height.
Logging will start automatically from any mode (NOT OFF) with no user input
required.
When LogTrackII passes the start logging trigger altitude, the device will sound one
beep, show “Logging” on the display and begin logging the altitude and 3-axis data.
When LogTrackII passes the stop logging Trigger altitude, the device will sound one
beep, switch off “Logging” on the display and stop logging.
Manual Start and Stop:
At any time, on the ground or in the airplane Manual Start / Stop is possible IF the Start
logging trigger altitude are set to 0,
Start:
First enter “Jump Mode”, (The LogTrackII shows Altitude)
Then Press
and
down and wait for 5 beeps and the Logging icon will
show.
Stop:
Press and
and wait for 5 beeps and the Logging icon will switch off.
Note:
When the “Logging” icon shows, the unit is logging data and an automatic or manual stop is
required to stop logging
Tuesday, May 18, 2010
Page