44428235
ASSEMBLY INSTRUCTION
Valid from:
17.07.2019
EPIC
®
SOLAR 4 PLUS
Document: L44428235EN
Version: 02
Page 6 of 9
We reserve all rights according to DIN ISO 16016.
Mounting of EPIC
®
SOLAR 4 PLUS
Analysing the cable
Find the cross section
Find the outer diameter
Item
Number
Designation
Cross section
in mm²
Cable
clamping
range
d in mm
Stripping
Length
L [mm]
Rated
Current
[A]
EPIC
®
SOLAR 4PLUS Female Connector, field mountable, including Contacts
44428236 EPIC
®
SOLAR 4PLUS F 4 mm² ...
6 mm²
4 – 6
5,2 - 7,1
8
30
44428238 EPIC
®
SOLAR 4PLUS F 10 mm²
10
5,2 – 7,1
12
30
EPIC
®
SOLAR 4PLUS Male Connector, field mountable, including Contacts
44428235 EPIC
®
SOLAR 4PLUS M 4mm² ...
6mm²
4 – 6
5,2 - 7,1
8
30
44428237 EPIC
®
SOLAR 4PLUS M 10 mm²
10
5,2 – 7,1
12
30
Preparing the cable
Carefully cut the cabel. The strands shall be without any oxidation or contamination.
Stripping the cable
Stripping length: depending on the table (see table above!).
The insulation must be removed clean and competed. No stranded wires may be cut off