1  General Information 
 

1.1  Concept of Design 

LAPLACE power amplifiers are air cooled RF broad band amplifiers which are designed for a wide range of 
applications, where good linearity and wide bandwidth together with high gain is needed. The solid state 
booster stage is of type “Class A/B” (push-pull) which combines very good stability with good 
intermodulation behavior. 
 
Special features: 

 

automatic amplification control (AVR); 

 

pulse response optimised; 

 

protection circuit for output stage; 

 

remote control input (e.g. door switch); 

 

Front panel BNC input connectors 

 
 
 
 

1.2  Specification

 

Electrical 

Bandwidth: 

 

0.1MHz–250MHz (RF0250) 
80MHz - 1GHz (RF1100) 

 

 

 

1GHz – 2GHz (RF1200) 

 

 

 

1GHz – 3GHz (RF1300) 

 

 

 

1GHz – 6GHz (RF1600) 

Output level: 

 

43dBm (± 1.0dB)  (RF1100) 

 

 

 

40dBm (± 1.0dB)  (RF1200) 

 

 

 

37dBm (± 1.0dB)  (RF1300) 

 

 

 

40dBm (± 1.0dB)  (RF1600) 

Power level: 

 

nom  24W (RF0250, RF1100) 

 

 

 

max.:  15W (RF1600) 

 

 

 

 

8W (RF1300) 

Non linearity:   

nom:  ±1.0dB 

 

 

 

max.:  ±1.5dB 

Input for nom  
output power:    

0dBm  (1.0mW) 

Max. gain: 

 

43dB 

Input Impedance: 

50ohm 

Input VSWR:   

1.5 : 1 

Input connector: 

BNC on front panel 

 

 

 

 

Output Impedance: 

50ohm 

Mismatch tolerance: 

100% 

Output connector: 

N type on front panel 

Operating mode: 

A/AB 

Modulation: 

 

100% 

Cooling: 

 

Active (internal fan) 

 
Interlocks: 

 

External contact input. 

 

 

 

Front panel push button 

 

 

 

Status indication 

 

 

 

Output for system controller 

 
 
General 
Weight: 
Size:   

 

300 x 96 x 240mm 

Supply voltage   

100-264VAC   

 

 

 

50/60Hz 

Total power: 

 

100W nom,  150W max 

 
 
 

 

.

 

 

 

Summary of Contents for RF0250

Page 1: ...Laplace Instruments Ltd User guide RF Power amplifier Page 1 RF0250 RF1100 RF1200 RF1300 RF1600 Power Amplifier User Manual Issue 5 September 2017 LAPLACE INSTRUMENTS LTD...

Page 2: ...Laplace Instruments Ltd User guide RF Power amplifier Page 2...

Page 3: ...ximum radiation levels which are stated by every country s laws will not be exceeded if this unit is used together with antennas It is suggested that the antenna or any other load is placed inside of...

Page 4: ...ing sign will be used whenever a fact must be considered very carefully Service No user serviceable parts are inside of this unit When replacing a fuse same type and rating of fuse must be used Openin...

Page 5: ...onnectors 1 2 Specification Electrical Bandwidth 0 1MHz 250MHz RF0250 80MHz 1GHz RF1100 1GHz 2GHz RF1200 1GHz 3GHz RF1300 1GHz 6GHz RF1600 Output level 43dBm 1 0dB RF1100 40dBm 1 0dB RF1200 37dBm 1 0d...

Page 6: ...reless transportation Also read the following instructions about installation and putting into operation 1 5 1 Where to Operate the Unit Choose a location where good air ventilation is possible Do not...

Page 7: ...unless it is correctly terminated Although it is designed to withstand any load abnormality this cannot be tolerated for extended periods especially when the amplifier is used within a control loop as...

Page 8: ...W Higher input levels and transients with high voltage peaks can damage the amplifier However short circuit or open circuit will cause overheating and failure of this amplifier Do not feed more than 1...

Page 9: ...NC connector is provided on the front panel and at the back an SMA connector is available To use the SMA connector remove the link across the back of the unit and apply the signal to the right hand SM...

Page 10: ...For support warranty and advice contact your local LAPLACE INSTRUMENTS LTD supplier or LAPLACE INSTRUMENTS LTD Tudor House Grammar School Road North Walsham Norfolk NR28 9JH Tel 016 92 40 20 70 Fax 01...

Reviews: