MK715x1 Remote Controller Application
Quick Reference Guide
4.
Log Function
FEXK715x1_RC_Quick_Guide-01
7
Message during transmission
Transmitter side
<info> app: seq=0x00 bat=100% gid=0x00 cid=0x01
(1)
(1) Transmitted data
seq
: Sequence number
bat
: Remaining battery level
gid
: Group ID value
cid
: Control ID value
Receiver side
<info> app: Save Adrs 0xYYYYYYYYYYYY to list
<info> app: ------------------------------------
<info> app: 02 01 04 0B FF 79 01 FF|.....y..
<info> app: FF 2A 64 00 04 00 00 0F|.*d.....
<info> app: 09 4C 41 50 49 53 4D 4B| LAPISMK
<info> app: 37 31 35 58 31 52 43 |715X1RC
<info> app: ------------------------------------
<info> app: seq=0x2A bat=100% gid=0x00 cid=0x04
<info> app: ------------------------------------
(1)
(2)
|
|
|
(3)
(1) Device address on the transmitter side
(2) Received packet
(3) Decoded result of received packet
seq
: Sequence number
bat
: Remaining battery level
gid
: Group ID value
cid
: Control ID value
Remaining battery measurement message
<info> app: Battery 3294 mv -> 100 %
Note that the LED1 of the transmitter lights up when its remaining battery level becomes 10% or lower.