2: Description and Specifications 

 

XPort Pro Integration Guide 

 

Ethernet Interface 

The Ethernet interface magnetics, RJ45 connector, and Ethernet status LEDs are all 
in the device server shell.  The XPort Pro PHY is Auto MDIX capable allowing 
connection to either straight through or cross over Ethernet cables. 

Table 2-2 Ethernet Interface Signals (Industry Standards) 

Signal Name 

DIR 

Contact 

Primary Function 

TX+ 

Out 

Differential Ethernet transmit data + 

TX- 

Out 

Differential Ethernet transmit data - 

RX+ 

In 

Differential Ethernet receive data + 

RX- 

In 

Differential Ethernet receive data - 

Not used 

 

Terminated 

Not used 

 

Terminated 

Not used 

 

Terminated 

Not Used 

 

Terminated 

SHIELD 

 

 

Chassis ground 

LEDs 

The XPort Pro contains the following LEDs: 

 

Link (solid green, left LED) 

 

Activity (blinking amber, right LED) 

 
 

Figure 2-3. XPort Pro LEDs 

 

 

 

 

 

Summary of Contents for xport pro

Page 1: ...Part Number 900 557 Revision E September 2011 Integration Guide...

Page 2: ...to take whatever measures may be required to correct the interference Note This product has been designed to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These...

Page 3: ...on Guide 5 Additional Documentation 5 2 Description and Specifications 6 The XPort Pro Features 6 XPort Pro Block Diagram 7 PCB Interface 7 Ethernet Interface 9 LEDs 9 Dimensions 10 Recommended PCB La...

Page 4: ...ure 2 4 Front View 10 Figure 2 5 Bottom View 10 Figure 2 6 Side View 10 Figure 2 7 PCB Layout 11 Figure 2 8 Product Label 12 List of Tables Table 2 1 PCB Interface Signals 8 Table 2 2 Ethernet Interfa...

Page 5: ...ix web site at www lantronix com support documentation for the latest documentation and the following additional documentation Document Description XPort Pro User Guide Provides information needed to...

Page 6: ...rity by offering a variety of robust data encryption and authentication options What s more the option to run Linux with IPv6 built in enables you to deploy custom applications and take advantage of t...

Page 7: ...00 bps The serial signals pins 4 8 are 3 3V CMOS logic level The serial interface pins include 3 3V ground and reset The serial signals connect to an internal UART driven at 3 3V For applications requ...

Page 8: ...Enable In RS485 mode CP1 is driven by the built in UART for connection to the transmit enable pin of an RS485 Transceiver CP2 DTR Configurable Pin 2 7 CP2 can be configured as follows Modem control DT...

Page 9: ...2 2 Ethernet Interface Signals Industry Standards Signal Name DIR Contact Primary Function TX Out 1 Differential Ethernet transmit data TX Out 2 Differential Ethernet transmit data RX In 3 Differenti...

Page 10: ...CONTACT 8 5 85 0 230 14 50 0 571 4 03 0 158 13 50 0 531 1 85 0 073 3 25 0 128 3 30 0 130 1 27 0 050 0 40 0 016 FRONT VIEW DIMS mm in LEFT LED SHIELD TAB SHIELD TAB TOLERANCE XX 0 20 0 008 Figure 2 5...

Page 11: ...oth signal ground and 3 3V This will cause any voltage spike from ESD to be imparted equally to both signal ground and 3 3V with no net voltage increase between 3 3V and signal ground For the highest...

Page 12: ...perating Temperature 40 85 o C Storage Temperature 40 85 o C Table 2 4 Recommended Operating Conditions Parameter Symbol Min Typical Max Units Supply Voltage VCC 3 15 3 3 3 46 Vdc Supply Voltage Rippl...

Page 13: ...FTP FTP Auto IP SMTP HTTPS and HTTP LEDs 10Base T and 100Base TX Link Activity Management Internal web server SNMP read only Serial login Telnet login DeviceInstaller utility SSH Security Password pro...

Page 14: ...tegration Guide 14 A A X XP Po or rt t P Pr ro o 4 48 85 5 C Co on nn ne ec ct ti io on n D Di ia ag gr ra am m The following example illustrates a connection between the XPort Pro and an external tra...

Page 15: ...ons Immunity FCC Part 15 Subpart B Class B ICES 003 Issue 4 2004 Class B EN55022 2006 and EN55024 1998 A1 2001 A2 2003 AS NZS CISPR22 2006 VCCI V 3 2009 04 EN61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A...

Page 16: ...l ethers PBDE UDS1100 and 2100 0 0 0 0 0 0 EDS 0 0 0 0 0 0 MSS100 0 0 0 0 0 0 IntelliBox 0 0 0 0 0 0 XPress DR XPress DR 0 0 0 0 0 0 SecureBox 1101 2101 0 0 0 0 0 0 WiBox 0 0 0 0 0 0 UBox 0 0 0 0 0 0...

Page 17: ...XPort Pro Integration Guide 17 C C W Wa ar rr ra an nt ty y For details on the Lantronix warranty replacement policy go to our web site at www lantronix com support warranty...

Reviews: