xPico
®
200 Certification Firmware Instructions
9
9.
Assert the module default pin and power up the module
. The Tera Term window will
display the firmware transfer progress.
10. When the firmware has successfully loaded, a Pass Test window will be displayed.
Note: In some cases, you may need to reset the Tera Term window after loading the
firmware.
11. At the CLI prompt, type
cert console
to enter continuous mode for running cert scripts.
12. Type
?
to list all commands. Type
wl -h
to list all wl commands.
Running the Wi-Fi Continuous Mode Tests
Wi-Fi continuous mode uses the Cypress WL commands. For more information on WL tool
commands please see the Cypress reference document at
http://www.cypress.com/file/385966/download
The Wi-Fi scripts directory includes several scripts that can be pasted into the Tera Term
command prompt.
Example scripts are shown below.