Lantronix TN-SFP 25G R-S Series User Manual Download Page 11

Lantronix 

 

 

 

 

      

 

 

TN-SFP-xx25G-xR-S Series User Guide 

33815 Rev. C 

                                     

https://www.lantronix.com/ 

Page 11 of 16 

SFP Information and SFP Detail Info 

Note: 

This feature is not available on all devices and may vary between products. See the related manual for 

more information. 

SFP Information    

This page displays general SFP information and monitoring information as shown and described below. 

 

Parameter descriptions

  Parameter

 

                                        Description 

Port

 

 

The logical port for the settings contained in the same row. 

Tx Central 

Wavelength

 

 

Displays the nominal transmitter output wavelength in nm. 

Bit rate

 

 

Displays the nominal bit rate of the transceiver. 

Temperature

 

 

Displays the internally measured transceiver temperature. Temperature accuracy is 

vendor specific but must be better than 3 degrees Celsius over specified operating 

temperature and voltage. 

Vcc

 

 

Displays the internally measured transceiver supply voltage. Accuracy is vendor 

specific but must be better than 3 percent of the manufacturer's nominal value over 

specified operating temperature and voltage. Note that in some transceivers, 

transmitter supply voltage and receiver supply voltage are isolated. In that case, 

only one supply is monitored. Refer to the device specification for more detail. 

Mon1 (Bias)  

Displays the measured TX bias current in uA. Accuracy is vendor specific but must 

be better than 10 percent of the manufacturer's nominal value over specified 

operating temperature and voltage. 

Mon2 (TX PWR)

 

 

Displays the measured coupled TX output power in mW. Accuracy is vendor 

specific but must be better than 3dB over specified operating temperature and 

Summary of Contents for TN-SFP 25G R-S Series

Page 1: ...TN SFP xx25G xR S Series Cisco Compatible 10G 25GBase SFP28 Modules 10G 25GBase X SFP28 With DMI LC User Guide Part Number 33815 Revision C February 2022...

Page 2: ...upport transition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contai...

Page 3: ...ns and Standards 5 Applications 6 Safety Instructions 6 SFP Unpacking 7 SFP Installation 7 Cautions 7 Installing an SFP Module 7 Fiber Cable Physical Characteristics 8 Connecting Fiber Cables 8 Removi...

Page 4: ...fronthaul transport network See the latest eCPRI specification at http www cpri info downloads eCPRI_v_1_1_2018_01_10 pdf RRH Remote Radio Head are distributed on the towers every few miles in cities...

Page 5: ...Standards IEEE 802 3z IEEE 802 3 IEEE 802 3ae IEEE 802 3CC Output Wavelength 5 5nm c 7 5nm Compliance IEC 60825 FDA 21 CFR 1040 10 and 1040 11 MSA 10GBase xR 25GBase xR 5G eCPRI SFF 8431 SFF 8472 RoHS...

Page 6: ...on the laser output power The primary hazards of exposure to laser radiation from an optical fiber system are Damage to the eye by accidental exposure to a beam emitted by a laser source Damage to the...

Page 7: ...dule is keyed to only be installed one way If forced the wrong way damage may occur Avoid getting dust or other contaminants into the fiber bore of the SFP transceiver module as this will cause the op...

Page 8: ...LED s See the related manual for details TN SFP BX40 U I TN SFP BX40 D I Fiber Cable Physical Characteristics The fiber cable physical characteristics must meet or exceed IEEE 802 3ae specifications...

Page 9: ...eiver module has an actuator button latch gently press the actuator button on the front of the SFP transceiver module until it clicks and the latch mechanism releases the SFP transceiver module from t...

Page 10: ...n sections are described below DDMI Parameter Description Vendor The SFP vendor s name Part Number The SFP vendor Part number provided by the SFP vendor TN 10GSFP SR Serial Number The SFP Vendor Seria...

Page 11: ...erature accuracy is vendor specific but must be better than 3 degrees Celsius over specified operating temperature and voltage Vcc Displays the internally measured transceiver supply voltage Accuracy...

Page 12: ...e appropriate standard It should be maintained down to the minimum transmitted power minus cable plant loss insertion loss or passive loss per the appropriate standard Absolute accuracy beyond this mi...

Page 13: ...ndor specific but must be better than 3dB over specified operating temperature and voltage Data is assumed to be based on measurement of a laser monitor photodiode current Data is not valid when the t...

Page 14: ...ul interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio n...

Page 15: ...nschliesslich der gegenseitigen Anerkennung ihrer Konformit t CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in dama...

Page 16: ...arters 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online http www transition com support Sales Offices For a cur...

Reviews: