background image

Lantronix 

 

SMxTAT2SA Install Guide

 

33716 Rev. L 

                  

https://www.lantronix.com/

   

24   

Calculate PoE Power Budget 

To calculate how many 802.3at devices the unit supports, divide the Total PoE Budget (130 Watts) by 30 Watts.   

To calculate the maximum number of 802.3af devices, divide the Total PoE Budget (130 Watts) by 15.4 Watts. 

Mixing POE and Non-POE Devices 

You can mix POE and non-POE devices on the same POE switch (i.e., you can put PCs on the same POE switch 

as a SIP phone or a VOIP phone). The PSE (your switch) will only send power if requested by the PD.   

Ethernet and PoE Intra-Building Cabling Warnings 

1.  Ethernet cables are intended for intrabuilding use only. Connecting your Lantronix switch directly to Ethernet 

cables that run outside the building in which the switch is housed will void the user's warranty and could 

create a fire or shock hazard.   

2.  PoE cables are intended for intrabuilding use only. Connecting your Lantronix switch directly to PoE cables 

that run outside the building in which the switch is housed will void the user's warranty and could create a fire 

or shock hazard. 

3.  For outdoor PoE applications, we recommend using Lantronix' SI-IES-1200-LRT Unmanaged Hardened 

PoE+ Injector or SI-IES-111D-LRT Unmanaged Hardened PoE+ Injector/Converter Use of any other PoE 

injector will void the user's warranty and could create a fire or shock hazard. 

Legacy PD Detection / Capacitor Detection 

Legacy PDs refers to powered devices manufactured before the IEEE standard was finalized and do not have the 

expected PD signature required by the PSE's detection signal. Such PDs usually feature large capacitance as the 

detection signature that does not completely comply with the 802.3af specs. By enabling this option, the switch   

will probe for legacy PDs and if a legacy PD is detected, the switch will provide power to the PD.   

Troubleshooting PoE Problems

 

 

1.  Get as much detail as possible regarding the symptom, including any system messages from the PoE switch.   

For example, does a PD not power up at all, or does it power up briefly and then power down? 

2.  Determine if the trouble occurred on initial installation or after the PD had been working normally? 

3.  If the trouble started after the PD was working, what changed? Any hardware or software changes? 

4.  Verify that the port is not shut down, disabled, or errored. 

5.  Verify that the Ethernet cable from the PD to the switch port is good. 

6.  Verify that the total cable length from the switch front panel to the connected PD is not more than 100 meters. 

Some of the power from the switch port is dissipated in the cable due to wire resistance, especially on cables 

as long as 100 meters. Only the remaining power is available to the PD. The 100-meter limit for twisted-pair 

Ethernet cable assumes 

a)

 not more than four RJ-45 connection points in the transmission path, 

b)

 90 meters 

of solid-strand Category 5 or 5e, and 

c) 

10 meters of flexible multistrand cable (2-to-5 meters of multistrand 

Category 5 patch cords). 

7.  Verify that the PSE switch power budget can power the PD. If the switch power budget is depleted, additional 

PDs will not power-on when connected to a PoE port. Verify that the switch power budget (available PoE) is 

not depleted before or after the PD is connected. Verify that enough power is available for the PD type. 

8.  Verify if non-powered Ethernet devices can establish an Ethernet link on any port and that PoE devices do not 

power up on the same port. 

9.  Review alarms reported previously by system messages. 

10. If a working IP Phone or WAP intermittently reloads or disconnects from inline power, verify all electrical 

connections from the switch to the PD. An unreliable connection results in power interruptions and intermittent 

PD operation, such as PD disconnects and reloads. 

11. Check for changes in the electrical environment at the switch site. What is happening at the PD when the 

disconnect occurs? Check for error messages reported by the switch at the same time of the disconnect. 

Summary of Contents for SM8TAT2SA

Page 1: ...SM8TAT2SA SM16TAT2SA and SM24TAT2SA Smart Managed Switches 8 16 24 Port Gigabit PoE 2 Port 100 1000 SFP Slots Install Guide Part Number 33716 Revision L June 2022...

Page 2: ...undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non i...

Page 3: ...Warning Equipment grounding is vital to ensure safe operation The installer must ensure that the power module is properly grounded during and after installation Failure to observe this warning could r...

Page 4: ...de Reset Button 15 Chapter 3 Installation 16 Package Contents 16 Mounting the Switch on a Wall 16 Mounting the Switch on Desk or Shelf 17 Mounting the Switch in a 19 inch Rack 17 Installing SFP Module...

Page 5: ...02 3af at Power over Ethernet PoE Auto Power Reset and Always on PoE IEEE 802 3az EEE Energy Efficient Ethernet standard for Green Ethernet Support Jumbo Frame up to 9K bytes RADIUS TACACS Authenticat...

Page 6: ...0 1000 SFP Slots Includes 19 rack mount brackets and country specific power cord SM24TAT2SA Smart Managed PoE layer 2 Switch with 52Gbps switching capacity and Smart management Web GUI SNMP Telnet CLI...

Page 7: ...s simultaneously Each of ports 1 8 support PoE PoE within available PoE Power SM16TAT2SA Max PoE budget 250 Watts 30 Watts for 8 ports simultaneously 15 4 Watts for 16 ports simultaneously Each of por...

Page 8: ...traffic to only the requesters Supports 1024 multicast groups IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router IGMP Pro...

Page 9: ...EEE 802 1ab LLDP Used by network devices for advertising their identities capabilities and neighbors on an IEEE 802ab local area network Support LLDP MED extensions Web GUI Built in switch configurati...

Page 10: ...rom misuse of the PDs Always on PoE Always On PoE soft reboot allows a warm reboot of the switch without affecting the PoE output to the PD providing continuous power even during firmware upgrade Abou...

Page 11: ...witch including descriptions of Front and Back Panels Reset the switch or to restore the switch to factory defaults Mode Reset button operation and functions Front and Back Panels The front panels are...

Page 12: ...Lantronix SMxTAT2SA Install Guide 33716 Rev L https www lantronix com 12 Figure 3 SM24TAT2SA Front and Back Panels...

Page 13: ...us LEDs Indicate the current status of each port You can check these LEDs to understand the port status in different modes after changing the mode by pressing the Mode Reset button The LED indicators...

Page 14: ...er Blinking The port is transmitting receiving packets and the connection speed is 10 100Mbps Off The port has no active network cable connected or it is not established a link to connected device Oth...

Page 15: ...evious configuration settings saved The First Time Wizard displays again after pressing the Reset button Restore the Switch to Factory Defaults to restore the original factory default settings back to...

Page 16: ...ted to install a surge protector or surge suppressor to protect the switch Compliant with 802 3at in Environment A when using an isolated power supply For 802 3at Environment B applications i e buildi...

Page 17: ...Mounting the Switch in a 19 inch Rack Step 1 Attach the mounting brackets to both sides of the chassis Insert screws and tighten then with a screwdriver to secure the brackets Figure 7 Attaching Brack...

Page 18: ...tion The Fiber Optic Association Inc is an international non profit educational association chartered to promote professionalism in fiber optics through education certification and standards Step 1 In...

Page 19: ...e Country Code extension to the end of the SKU e g SM8TAT2SA NA North America LA Latin America EU Europe UK United Kingdom SA South Africa JP Japan OZ Australia BR Brazil Step 1 Connect the AC power c...

Page 20: ...tch To change the PC s IP address for a PC running Windows 7 8 x 10 is as follows a Type network and sharing into the Search box in the Start Menu b Select Network and Sharing Center c Click on Change...

Page 21: ...temporary internet files Check your PC settings again and repeat step 2 6 Enter the factory default username and password in login page 7 Click Login to log into the switch Note The factory default U...

Page 22: ...ng operating temperature range and take corresponding actions to resolve Port Status LED is Off in Link Act Speed Mode The port is not connected or the connection is not working 1 Check if the cable c...

Page 23: ...e strongly suggested to install a surge protector or surge suppressor to protect the switch The switch is compliant with 802 3at in Environment A when using an isolated power supply For 802 3at Enviro...

Page 24: ...l as possible regarding the symptom including any system messages from the PoE switch For example does a PD not power up at all or does it power up briefly and then power down 2 Determine if the troub...

Page 25: ...ect an overcurrent threshold and disconnect power from the line This prevents excessive current from being delivered by the PoE port which could possibly result in damage to port level components 15 A...

Page 26: ..._______________________ A description of any action s already taken to resolve the problem e g changing mode rebooting etc _____________________________________________________________________________...

Page 27: ...ns This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent...

Page 28: ...ce Standard IEC62368 1 UL Listed Normas Oficiales Mexicans NOM SMxTAT2SA Summary of compliance with National Differences Standard IEC62368 1 This product fulfils the requirements of IEC62368 1 The equ...

Page 29: ...worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Sicure...

Page 30: ...ve Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or https www lantronix com technical support Sales Offices Fo...

Reviews: