3: Installation
SLC™ Console Manager User Guide
33
The SLC0xx12N models have a single supply/input, while the SLC0xx22N models have dual
inputs and dual supplies. The power connector also houses a replaceable protective fuse
(fast-blow 4.0A, maximum 250V AC) and the on/off switch. In addition, we provide the
SLC0xx22N with a “Y” cord. See the SLC models listed in
.
shows the AC power inputs and power switch.
Figure 3-4 AC Power Input and Power Switch (SLCxxxx2N)
Note:
The SLC48 console manager with dual AC does not have an on/off switch.
DC Input
The DC version of the SLC console manager accepts standard –48 VDC power. The SLC0xx24T
models accept two DC power inputs for supply redundancy. Lantronix provides the DC power
connections using industry standard Wago connectors. One set of connectors is included with the
SLC console manager. You can order additional connectors (part number 721-103/031-000) from
the Wago catalog at
http://www.wagocatalog.com/okv3/index.asp?lid=1&cid=1&str_from_home=first
.
shows the DC power inputs and power switch.
Figure 3-5 DC Power Inputs and Power Switch (SLCxxx24T)