background image

 

 

 

 

 

SI-IES-1200-LRT 

Hardened Gigabit PoE/PoE+ Injector 

User Guide 

 
 
 
 

Part Number 33586 

Revision F June 2022 

Summary of Contents for SI-IES-1200-LRT

Page 1: ...SI IES 1200 LRT Hardened Gigabit PoE PoE Injector User Guide Part Number 33586 Revision F June 2022 ...

Page 2: ...es For a current list of our domestic and international sales offices go to www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non infringement fitness q...

Page 3: ...e is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the...

Page 4: ...t Panel 8 Top View 8 Grounding the PoE Injector 8 Wiring the Power Inputs 9 RJ 45 Pin Assignments 10 10 100Base TX Cable Schema 11 10 100 1000Base T Pinouts 11 10 100 1000Base T Cable Schema 12 Power Supply Specifications 13 25130 Features and Specifications 13 25130 Dimensions 14 Installation 15 DIN Rail Mounting 15 Assembling the DIN Rail Clip 15 Mounting the PoE Injector DIN Rail 16 Wall Mount ...

Page 5: ...osures or other challenging environments Product Description The SI IES 1200 LRT is a Hardened Gigabit PoE PoE Injector that provides data and DC power through the Ethernet cable to PoE equipped devices such as an IP camera access point PoE splitter or other equipment supporting IEEE 802 3af IEEE802 3at The SI IES 1200 LRT is typically installed near the Ethernet switch The figure below provides a...

Page 6: ...ry power connected PWR2 Power ON backup power connected Power Input 24 48VDC Power Consumption 33 36 Watts 24 VDC 3 53 Watts No PoE 33 36 Watts 1 port PoE Operating Temp 40 C 75 C 40 F 167 F Storage Temp 40 C 85 C 40 F 185 F Humidity 5 95 Humidity non condensing Operating Storage Weight 1 3 lbs 0 59 kg EMC CE FCC Class A EN61000 6 4 EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN6100...

Page 7: ... SI IES 1200 LRT User Manual 33586 Rev F https www lantronix com Page 7 of 19 Hardware Description Dimensions The Power over Ethernet Injector dimensions are Width 1 2 30 mm x Depth 3 7 95 mm x Height 5 5 140 mm ...

Page 8: ...n their respective power inputs are active PoE This LED indicator lights when PoE power is being delivered Top View The SI IES 1200 LRT is designed with two redundant power inputs which allows you to supply redundant input power in the range of 24 to 48V Power Inputs Grounding the PoE Injector Follow the instructions below to attach the PoE Injector to ground Attention When installing the PoE Inje...

Page 9: ...wer 2 and Power 1 4 Insert the exposed wires into the terminal block plugs Only wires with insulation should extend from the terminal block plugs Note that the polarities between the wires and the terminal block plugs must be positive to positive and negative to negative 5 Use a slotted screwdriver to tighten the captive screws ATTENTION Use Copper Conductors Only At 60 75 C tighten to 5 lb in The...

Page 10: ...aight through or crossover cabling See the figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note the and signs represent the polarity of the wires that make up each wire pair The table below shows the 10Base T 100Base TX MDI and MDI X port pinouts Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmi...

Page 11: ...inouts The table below describes the gigabit Ethernet RJ 45 pinouts Pin Signal Name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5 BI_DC Bi directional pair C 6 BI_DB Bi directional pair B 7 BI_DD Bi directional pair D 8 BI_DD Bi directional pair D ...

Page 12: ...Lantronix SI IES 1200 LRT User Manual 33586 Rev F https www lantronix com Page 12 of 19 10 100 1000Base T Cable Schema The following two figures illustrate the 10 100 1000Base T cable schema ...

Page 13: ... 56VDC Voltage Tolerance 1 0 Line Regulation 1 0 Load Regulation 1 0 Setup Rise Time 500ms 30ms Hold Up Time 20ms 115VAC Input Voltage Range Switch Selectable 88 264VAC 120 370VDC Frequency Range 47 63Hz Efficiency 88 AC Current Typical 1 1A 115VAC 0 7A 230VAC Inrush Current Cold 30A 115VAC 60A 230VAC Leakage Current 1mA 240VAC Protection Overload 105 150 Overvoltage 57 6 64 8V Environment Operati...

Page 14: ...Lantronix SI IES 1200 LRT User Manual 33586 Rev F https www lantronix com Page 14 of 19 25130 Dimensions Width 1 57 40 mm Depth 3 94 100 mm Height 3 54 90 mm ...

Page 15: ... Rail Mounting Assembling the DIN Rail Clip The DIN Rail clip is screwed on the device at the factory If not refer to the following steps and figure to secure the DIN Rail clip on the device 1 Use the screws to secure the DIN Rail clip at the rear of the device 2 To remove the DIN Rail clip reverse step 1 ...

Page 16: ...eps below to hang the device on a standard DIN rail 1 Position the rear side of the device directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the device downward 3 Check the DIN Rail clip is tightly fixed on the DIN rail 4 To remove the device from the track reverse the steps above ...

Page 17: ...unt plates 1 To remove the DIN Rail clip from the device unscrew the screws that secure it 2 Align the screw holes of the wall mount plates with the ones of the device 3 Use the screws included to secure the wall mount plates on the device 4 Use the hook holes of the wall mount plates to hang the device on the wall 5 To remove the wall mount plates reverse the steps above ...

Page 18: ...ed in you may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet If you still cannot resolve the problem contact your local dealer for assistance If the cables are properly connected and the LEDs show normal operation but data cannot be transmitted check your system Ethernet devices configuration and status Declaration of Conformity Mode...

Page 19: ...535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...