Commands
Initialize
6 - 29
UDP
Adds a UDP host entry to the host table.
envString
Enter a :T to change a TCP host connection from Telnet to raw TCP, or a
socket number to use a TCP or UDP socket other than the default.
Delete
Removes one or all entries from the hostlist.
number
Specify which host entry to remove. To view configured host entries,
enter the Show Hostlist command.
See Also
Multihost Mode, page 5-9; Change Dedicated, page 6-6; Show Hostlist,
page 6-32.
6.67 Initialize
Reboots the server. When Reload or Factory Initialization takes place, all user-entered commands
are lost; the server must be reconfigured.
Restrictions
Requires privileged user status.
Parameters
Delay
Reboots the server after a specified number of minutes.
number
Enter the number of minutes you wish to delay. To reboot immediately,
enter the number zero.
Factory
Reboots the server with its factory-configured settings.
Noboot
Cycles power on the server, but without booting. The server will remain
in the Boot Configuration Program.
Reload
Downloads operational software upon reboot.
See Also
Appendix E, Updating Software.
INITIALIZE
DELAY number
FACTORY
NOBOOT
RELOAD