4: Configuration Using XML
EDS-MD® Wired IoT Device Gateway Command Reference
21
XML Configuration Groups
lists the EDS-MD 4/8/16 wired IoT device gateway XCR groups in alphabetical order.
This table indicates the various group items, as well as some possible value names and options.
Note:
Any instance of
<
in the table may be read as "less than" and any instance of
>
may be read as "greater than".
Table 4-7 XCR Groups
Group Name
Group Item
Value Name
Value Options
Additional
Information
action:instance
(“instance” attribute
is “ethN link state
change”)
delay
N seconds, where N
is an integer that
represents the delay
in seconds
Default: 5 seconds
alarm email
None or Email N
where N is an integer
between 1 and 16
that represents the
email profile number
alarm message
alarm reminder
interval
<None> or N
where N is an integer
that represents the
interval in minutes
Default:
<None>
normal email
None or Email N
where N is an integer
between 1 and 16
that represents the
email profile number
normal message
normal reminder
interval
<None> or N
where N is an integer
that represents the
interval in minutes
Default:
<None>
ftp put
reminder interval
<None>
Default:
<None>
mode
Default: Simultaneous
connection N host
connection N port
Default: 21
connection N
filename
Default: data.txt
connection N protocol
Default: FTP
connection N
username
Default: anonymous
connection N
password