6: Setup Mode: Channel Configuration
DeviceLinx™ XPort Direct/XChip Direct SoC User Guide
34
Send the Escape Sequence (+++) in Modem Mode
Send ‘+++’ in Modem Mode (Y) ? _
Disable or enable the XPort Direct’s ability to send the escape sequence. The default
is
Y
(Yes) (send the escape sequence).
Show IP addr after 'RING'
Disable or enable the XPort Direct's ability to show the IP address after RING in
Modem Mode. The default is
Y
(Yes), to show the IP address.
Auto Increment Source Port
Auto increment source port (N) ? _
Y
(Yes) auto increments the source port. The XPort Direct increments the port
number used with each new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : (000) (000) (000) (000)_
Note:
This option does not display when Hostlist is enabled from the
ConnectMode
prompt (see
on page 27 for more information).
Remote Port
You must set the remote TCP port number for the unit to make outgoing connections.
This parameter defines the port number on the target host to which a connection is
attempted.
Remote Port (0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, use the
remote port number 23 (Internet standard port number for Telnet services).
Note:
This option does not display when Hostlist is enabled from the
ConnectMode
prompt (see
on page 27 for more information).
DisConnMode
This setting determines the conditions under which the unit will cause a network