Configuring an MSS4 or MSS-VIA Device Server
This section describes how to configure Com Port Redirector for use with an
MSS4 or MSS-VIA device server.
Device Server Configuration
1. Assign an IP address to the device server before using Com Port Redirector.
2. Telnet into the device server and log in as the privileged user.
The command to login as the privileged user is
set priv
.
The default password is
system
.
3. Set the serial settings (baud rate, parity, flow control, data bits) to those of
the serial device attached to the Lantronix device server.
4. Issue the following commands at the
Local_>>
prompt. Replace the
n
with
the port number to which Com Port Redirector will connect. Press the Enter
key (shown as
<CR>
) after typing each command. The last command reboots
the unit.
change port
n
autostart disable <CR>
change port
n
access remote <CR>
init delay 0 <CR>
Redirector Configuration
1. Click
the
Start
button in the Windows Taskbar, point to
Programs
, point to
Lantronix Redirector
, and click
Configuration
. The Com Port Redirector
Configuration window appears (see Figure 4-6).
Figure 4-6. Com Port Redirector Configuration Window
2. Using
the
Redirect To
drop-down list at the top of the Com Port Redirector
Configuration window, click a redirected com port.