Lantech
IPGS-0204DSFP
4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch
IGS-0204DSFP
4 10/100/1000T + 2 Dual Speed SFP Industrial Unmanaged Switch
User Manual
V1.00
Jul-2016
Page 1: ...Lantech IPGS 0204DSFP 4 10 100 1000T PoE at af 2 Dual Speed SFP Industrial Unmanaged Switch IGS 0204DSFP 4 10 100 1000T 2 Dual Speed SFP Industrial Unmanaged Switch User Manual V1 00 Jul 2016...
Page 2: ...rdware Description 4 Dimensions 4 Wiring the Power Inputs 5 Wiring the Fault Alarm Contact 6 LED Indicators 7 Dip Switch IES 0204DFT IPES 0204DFT 4 8 RJ 45 Pin Assignments 9 Cabling 11 Mounting Instal...
Page 3: ...Installation Steps 19 Troubleshooting 20...
Page 4: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...
Page 5: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...
Page 6: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...
Page 7: ...k of power failure the Industrial switch provides dual power inputs When power failure occurs the device will automatically switch to the secondary power input Flexible Mounting The industrial switch...
Page 8: ...tandard PoE models Supports MDI MDI X auto crossover Relay contact to connect with alarm system Provides flexible mounting DIN rail Panel Mounting Model Name 10 100 1000T 100 1000M SFP Power Supply Op...
Page 9: ...strial Ethernet Switch w terminal block and DIN Rail kit Caps for RJ45 port and SFP port Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection device on...
Page 10: ...4 Hardware Description In this paragraph we will introduce the Industrial switch s dimensions port cabling information and wiring installation Dimensions 43 x 152 x 105 mm W x H x D...
Page 11: ...ower wires Note The wire gauge for the terminal block should be in the range between 12 24 AWG V V V V1 1 Insert the positive and negative wires into the V and V contacts on the terminal block connect...
Page 12: ...switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wir...
Page 13: ...7 LED Indicators IPGS 0204DSFP 12V IPGS 0204DSFP 48V IGS 0204DSFP...
Page 14: ...inputs 5 6 Green On A network device is detected Blinking The port is transmitting or receiving packets from the TX device LNK ACT Green On A network device is detected Blinking The port is transmitti...
Page 15: ...e figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wir...
Page 16: ...below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5...
Page 17: ...STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5e above cable for 1000Mbps connections The cable between the switc...
Page 18: ...al speed 100M or 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper mult...
Page 19: ...13 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver...
Page 20: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...
Page 21: ...d on the industrial switch when out of factory If not please refer to the following steps and figure to secure the DIN rail clip on the switch 1 Use the screws to screw on the DIN rail clip on the ind...
Page 22: ...1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the unit downward 3 Check the DIN Rail clip is t...
Page 23: ...ustrial switch unscrew the screws to remove the DIN Rail clip 2 Place the wall mount plates on the rear panel of the industrial switch 3 Use the screws to secure the wall mount plates on the industria...
Page 24: ...18 Hardware Installation In this paragraph we will describe how to install the Industrial Unmanaged Switch and the installation points for the attention...
Page 25: ...power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twiste...
Page 26: ...at the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily monitored through panel indicators which describes common problems y...